Time:2007-06-06 15:00:50
Model Name:S12F-R1420
Serial Number:70b389
Controller Name:PS-5b SAS

Index	Severity	Time			Description
7	Notification	2007-06-04 15:51:31	NOTICE:Force Controller Write-Through on Trigger Cause (Primary in slot A)
8	Notification	2007-06-04 16:03:10	ID:56E21024 Logical Drive NOTICE: On-Line Initialization of Logical Drive Completed (Primary in slot A)
9	Notification	2007-06-04 17:22:20	Controller Initialization Completed (Primary in slot A)
10	Notification	2007-06-04 17:22:20	NOTICE:Controller BBU is Charging ! (Primary in slot A)
11	Notification	2007-06-04 17:22:21	NOTICE:Force Controller Write-Through on Trigger Cause (Primary in slot A)
12	Notification	2007-06-04 17:22:19	Controller Initialization Completed (Secondary in slot B)
13	Notification	2007-06-04 17:22:19	NOTICE:Controller BBU is Charging ! (Secondary in slot B)
14	Notification	2007-06-04 17:22:25	NOTICE:Controller Default Write Policy Restore (Primary in slot A)
15	Notification	2007-06-04 17:22:41	NOTICE:Force Controller Write-Through on Trigger Cause (Primary in slot A)
16	Notification	2007-06-04 18:15:16	Controller Initialization Completed (Primary in slot A)
17	Notification	2007-06-04 18:15:17	NOTICE:Controller BBU is Charging ! (Primary in slot A)
18	Notification	2007-06-04 18:15:10	Controller Initialization Completed (Secondary in slot B)
19	Notification	2007-06-04 18:15:10	NOTICE:Controller BBU is Charging ! (Secondary in slot B)
20	Notification	2007-06-04 18:15:37	NOTICE:Force Controller Write-Through on Trigger Cause (Primary in slot A)
21	Notification	2007-06-04 18:20:47	ID:1743416A Logical Drive NOTICE: Starting Creation (Primary in slot A)
22	Notification	2007-06-04 18:21:00	ID:1743416A Logical Drive NOTICE: Creation of Logical Drive Completed (Primary in slot A)
23	Notification	2007-06-04 18:21:00	ID:1743416A Logical Drive NOTICE: Starting On-Line Initialization (Primary in slot A)
24	Critical	2007-06-04 18:25:31	CHL:5 ID:0  Drive : Media Error Encountered - AE3481 (30C) (Primary in slot A)
25	Notification	2007-06-04 18:25:32	CHL:5 ID:0  Drive NOTICE: Block Successfully Reassigned - 0xAE3481 (Primary in slot A)
26	Warning		2007-06-04 18:26:17	CHL:5 ID:0  Target WARN: Unexpected Select Timeout (Primary in slot A)
27	Critical	2007-06-04 18:26:41	ID:1743416A Logical Drive ALERT: CHL:5 ID:0  Drive Failure (Primary in slot A)
28	Notification	2007-06-04 19:07:55	ID:1743416A Logical Drive NOTICE: On-Line Initialization of Logical Drive Completed (Primary in slot A)
29	Notification	2007-06-04 20:04:51	Controller Initialization Completed (Primary in slot A)
30	Notification	2007-06-04 20:04:51	NOTICE:Controller BBU is Charging ! (Primary in slot A)
31	Notification	2007-06-04 20:04:45	Controller Initialization Completed (Secondary in slot B)
32	Notification	2007-06-04 20:04:45	NOTICE:Controller BBU is Charging ! (Secondary in slot B)
33	Notification	2007-06-04 20:05:05	NOTICE:Force Controller Write-Through on Trigger Cause (Primary in slot A)
34	Notification	2007-06-04 20:12:41	ID:4DCF4F87 Logical Drive NOTICE: Starting Off-Line Initialization (Primary in slot A)
35	Notification	2007-06-04 20:51:12	ID:4DCF4F87 Logical Drive NOTICE: Off-Line Initialization of Logical Drive Completed (Primary in slot A)
36	Notification	2007-06-04 20:53:53	NOTICE: Controller BBU Fully Charged ! (Primary in slot A)
37	Notification	2007-06-04 20:56:11	NOTICE: Controller BBU Fully Charged ! (Secondary in slot B)
38	Notification	2007-06-04 20:56:13	NOTICE:Controller Default Write Policy Restore (Primary in slot A)
39	Warning		2007-06-05 09:00:36	CHL:5  Drive Channel WARN: SCSI Channel Failure (Primary in slot A)
40	Notification	2007-06-05 09:00:37	Controller Initialization Completed (Primary in slot A)
41	Notification	2007-06-05 09:00:38	NOTICE:Force Controller Write-Through on Trigger Cause (Primary in slot A)
42	Notification	2007-06-05 09:00:30	Controller Initialization Completed (Secondary in slot B)
43	Notification	2007-06-05 09:00:42	NOTICE:Controller Default Write Policy Restore (Primary in slot A)
44	Warning		2007-06-05 11:06:27	CHL:5  Drive Channel WARN: SCSI Channel Failure (Primary in slot A)
45	Notification	2007-06-05 11:06:28	Controller Initialization Completed (Primary in slot A)
46	Notification	2007-06-05 11:06:28	ALERT:Controller BBU is Charging ! (Primary in slot A)
47	Notification	2007-06-05 11:06:29	NOTICE:Force Controller Write-Through on Trigger Cause (Primary in slot A)
48	Warning		2007-06-05 11:15:48	CHL:5  Drive Channel WARN: SCSI Channel Failure (Primary in slot A)
49	Notification	2007-06-05 11:15:49	Controller Initialization Completed (Primary in slot A)