Version                     IPMI v2.0
Number of Entries           756
Last Add Time               01/20/2011-10:17:24
Last Erase Time             Pre-Init Time Stamp
Free Space Remaining in Bytes        51894

Num 	Time Stamp 	Sensor Type, Name & Number 	Event Description 	Generator ID
1   	12/01/2008-00:17:56  	Physical Security (Chassis Intrusion	Informational event: Physical Scrty reports the chassis is now closed.                                                                                                                                                                                    	BMC - LUN #0 (Channel #00h)                 
2   	12/01/2008-00:17:56  	Physical Security (Chassis Intrusion	Warning event: Physical Scrty reports there has been a chassis intrusion.                                                                                                                                                                                 	BMC - LUN #0 (Channel #00h)                 
3   	12/01/2008-00:18:02  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is first of two expected events from BIOS on every power on.                                                                                                                     	BIOS (Channel #00h)                         
4   	12/01/2008-00:18:02  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is second of two expected events from BIOS on every power on.                                                                                                                    	BIOS (Channel #00h)                         
5   	12/01/2008-00:20:07  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports a system boot event has occurred.                                                                                                                                                                            	BIOS (Channel #00h)                         
6   	12/01/2008-00:25:45  	System Event #0x83                  	Informational event: System Event sensor 131 reports Timestamp Clock Sync. Event is first of two expected events from BIOS on every power on.                                                                                                             	BIOS (Channel #00h)                         
7   	12/01/2008-00:25:45  	Physical Security (Chassis Intrusion	Informational event: Physical Scrty reports the chassis is now closed.                                                                                                                                                                                    	BMC - LUN #0 (Channel #00h)                 
8   	12/01/2008-00:25:45  	Physical Security (Chassis Intrusion	Warning event: Physical Scrty reports there has been a chassis intrusion.                                                                                                                                                                                 	BMC - LUN #0 (Channel #00h)                 
9   	12/01/2008-00:25:47  	Power Unit /Pwr Unit Status (#0x01) 	Informational event: Pwr Unit Status reports the power unit is powered off or being powered down.                                                                                                                                                         	BMC - LUN #0 (Channel #00h)                 
10  	12/01/2008-00:25:47  	Power Unit /Pwr Unit Status (#0x01) 	CRITICAL event: Pwr Unit Status reports the power unit has suffered a failure.                                                                                                                                                                            	BMC - LUN #0 (Channel #00h)                 
11  	04/21/2009-13:16:27  	Power Unit /Pwr Unit Status (#0x01) 	Informational event: Pwr Unit Status reports the power unit is powered off or being powered down.                                                                                                                                                         	BMC - LUN #0 (Channel #00h)                 
12  	04/21/2009-13:16:27  	Power Unit /Pwr Unit Status (#0x01) 	CRITICAL event: Pwr Unit Status reports the power unit's AC is lost.                                                                                                                                                                                      	BMC - LUN #0 (Channel #00h)                 
13  	04/21/2009-13:16:29  	Processor /P1 Status (#0x60)        	Informational event: P1 Status reports the processor's presence has been detected.                                                                                                                                                                        	BMC - LUN #0 (Channel #00h)                 
14  	04/21/2009-13:16:29  	Processor /P2 Status (#0x61)        	Informational event: P2 Status reports the processor's presence has been detected.                                                                                                                                                                        	BMC - LUN #0 (Channel #00h)                 
15  	04/21/2009-13:16:30  	Power Unit /Pwr Unit Status (#0x01) 	Informational event: Pwr Unit Status reports the power unit is powered off or being powered down.                                                                                                                                                         	BMC - LUN #0 (Channel #00h)                 
16  	04/21/2009-13:16:30  	Power Unit /Pwr Unit Status (#0x01) 	Informational event: Pwr Unit Status reports the power unit's AC has been regained.                                                                                                                                                                       	BMC - LUN #0 (Channel #00h)                 
17  	04/21/2009-13:16:35  	Power Supply /PS1 Status (#0x50)    	Warning event: PS1 Status reports the power supply's input (AC/DC) has been lost.                                                                                                                                                                         	BMC - LUN #0 (Channel #00h)                 
18  	04/21/2009-13:16:36  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is first of two expected events from BIOS on every power on.                                                                                                                     	BIOS (Channel #00h)                         
19  	04/21/2009-13:16:37  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is second of two expected events from BIOS on every power on.                                                                                                                    	BIOS (Channel #00h)                         
20  	04/21/2009-13:16:37  	Power Supply /PS1 Status (#0x50)    	Informational event: PS1 Status reports the power supply's input (AC/DC) has been regained.                                                                                                                                                               	BMC - LUN #0 (Channel #00h)                 
21  	04/21/2009-13:16:42  	Fan #0x31                           	Warning event: Fan sensor 49 reports the sensor is in a low, but non-critical, and going lower state.  Sensor reading: Unspecified.  Threshold value: Unspecified.                                                                                        	BMC - LUN #0 (Channel #00h)                 
22  	04/21/2009-13:16:42  	Fan #0x31                           	CRITICAL event: Fan sensor 49 reports the sensor is in a low, critical, and going lower state.  Sensor reading: Unspecified.  Threshold value: Unspecified.                                                                                               	BMC - LUN #0 (Channel #00h)                 
23  	04/21/2009-13:16:42  	Fan #0x32                           	Warning event: Fan sensor 50 reports the sensor is in a low, but non-critical, and going lower state.  Sensor reading: Unspecified.  Threshold value: Unspecified.                                                                                        	BMC - LUN #0 (Channel #00h)                 
24  	04/21/2009-13:16:42  	Fan #0x32                           	CRITICAL event: Fan sensor 50 reports the sensor is in a low, critical, and going lower state.  Sensor reading: Unspecified.  Threshold value: Unspecified.                                                                                               	BMC - LUN #0 (Channel #00h)                 
25  	04/21/2009-13:16:42  	Fan #0x33                           	Warning event: Fan sensor 51 reports the sensor is in a low, but non-critical, and going lower state.  Sensor reading: Unspecified.  Threshold value: Unspecified.                                                                                        	BMC - LUN #0 (Channel #00h)                 
26  	04/21/2009-13:16:42  	Fan #0x33                           	CRITICAL event: Fan sensor 51 reports the sensor is in a low, critical, and going lower state.  Sensor reading: Unspecified.  Threshold value: Unspecified.                                                                                               	BMC - LUN #0 (Channel #00h)                 
27  	04/21/2009-13:16:42  	Fan #0x34                           	Warning event: Fan sensor 52 reports the sensor is in a low, but non-critical, and going lower state.  Sensor reading: Unspecified.  Threshold value: Unspecified.                                                                                        	BMC - LUN #0 (Channel #00h)                 
28  	04/21/2009-13:16:42  	Fan #0x34                           	CRITICAL event: Fan sensor 52 reports the sensor is in a low, critical, and going lower state.  Sensor reading: Unspecified.  Threshold value: Unspecified.                                                                                               	BMC - LUN #0 (Channel #00h)                 
29  	04/21/2009-13:16:42  	Fan #0x36                           	Warning event: Fan sensor 54 reports the sensor is in a low, but non-critical, and going lower state.  Sensor reading: Unspecified.  Threshold value: Unspecified.                                                                                        	BMC - LUN #0 (Channel #00h)                 
30  	04/21/2009-13:16:42  	Fan #0x36                           	CRITICAL event: Fan sensor 54 reports the sensor is in a low, critical, and going lower state.  Sensor reading: Unspecified.  Threshold value: Unspecified.                                                                                               	BMC - LUN #0 (Channel #00h)                 
31  	04/21/2009-13:16:42  	Fan #0x37                           	Warning event: Fan sensor 55 reports the sensor is in a low, but non-critical, and going lower state.  Sensor reading: Unspecified.  Threshold value: Unspecified.                                                                                        	BMC - LUN #0 (Channel #00h)                 
32  	04/21/2009-13:16:42  	Fan #0x37                           	CRITICAL event: Fan sensor 55 reports the sensor is in a low, critical, and going lower state.  Sensor reading: Unspecified.  Threshold value: Unspecified.                                                                                               	BMC - LUN #0 (Channel #00h)                 
33  	04/21/2009-13:17:51  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports a system boot event has occurred.                                                                                                                                                                            	BIOS (Channel #00h)                         
34  	04/21/2009-13:18:00  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is first of two expected events from BIOS on every power on.                                                                                                                     	BIOS (Channel #00h)                         
35  	04/21/2009-13:18:01  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is second of two expected events from BIOS on every power on.                                                                                                                    	BIOS (Channel #00h)                         
36  	04/21/2009-13:18:19  	Fan #0x31                           	Informational event: Fan sensor 49 reports the sensor is no longer in a low non-critical state.  Sensor reading: Unspecified.  Threshold value: Unspecified.                                                                                              	BMC - LUN #0 (Channel #00h)                 
37  	04/21/2009-13:18:19  	Fan #0x31                           	Informational event: Fan sensor 49 reports the sensor is no longer in a critically low state.  Sensor reading: Unspecified.  Threshold value: Unspecified.                                                                                                	BMC - LUN #0 (Channel #00h)                 
38  	04/21/2009-13:18:19  	Fan #0x32                           	Informational event: Fan sensor 50 reports the sensor is no longer in a low non-critical state.  Sensor reading: Unspecified.  Threshold value: Unspecified.                                                                                              	BMC - LUN #0 (Channel #00h)                 
39  	04/21/2009-13:18:19  	Fan #0x32                           	Informational event: Fan sensor 50 reports the sensor is no longer in a critically low state.  Sensor reading: Unspecified.  Threshold value: Unspecified.                                                                                                	BMC - LUN #0 (Channel #00h)                 
40  	04/21/2009-13:18:19  	Fan #0x33                           	Informational event: Fan sensor 51 reports the sensor is no longer in a low non-critical state.  Sensor reading: Unspecified.  Threshold value: Unspecified.                                                                                              	BMC - LUN #0 (Channel #00h)                 
41  	04/21/2009-13:18:19  	Fan #0x33                           	Informational event: Fan sensor 51 reports the sensor is no longer in a critically low state.  Sensor reading: Unspecified.  Threshold value: Unspecified.                                                                                                	BMC - LUN #0 (Channel #00h)                 
42  	04/21/2009-13:18:19  	Fan #0x34                           	Informational event: Fan sensor 52 reports the sensor is no longer in a low non-critical state.  Sensor reading: Unspecified.  Threshold value: Unspecified.                                                                                              	BMC - LUN #0 (Channel #00h)                 
43  	04/21/2009-13:18:19  	Fan #0x34                           	Informational event: Fan sensor 52 reports the sensor is no longer in a critically low state.  Sensor reading: Unspecified.  Threshold value: Unspecified.                                                                                                	BMC - LUN #0 (Channel #00h)                 
44  	04/21/2009-13:18:19  	Fan #0x36                           	Informational event: Fan sensor 54 reports the sensor is no longer in a low non-critical state.  Sensor reading: Unspecified.  Threshold value: Unspecified.                                                                                              	BMC - LUN #0 (Channel #00h)                 
45  	04/21/2009-13:18:19  	Fan #0x36                           	Informational event: Fan sensor 54 reports the sensor is no longer in a critically low state.  Sensor reading: Unspecified.  Threshold value: Unspecified.                                                                                                	BMC - LUN #0 (Channel #00h)                 
46  	04/21/2009-13:18:19  	Fan #0x37                           	Informational event: Fan sensor 55 reports the sensor is no longer in a low non-critical state.  Sensor reading: Unspecified.  Threshold value: Unspecified.                                                                                              	BMC - LUN #0 (Channel #00h)                 
47  	04/21/2009-13:18:19  	Fan #0x37                           	Informational event: Fan sensor 55 reports the sensor is no longer in a critically low state.  Sensor reading: Unspecified.  Threshold value: Unspecified.                                                                                                	BMC - LUN #0 (Channel #00h)                 
48  	04/21/2009-13:18:20  	Fan #0x31                           	Warning event: Fan sensor 49 reports the sensor is in a low, but non-critical, and going lower state.  Sensor reading: Unspecified.  Threshold value: Unspecified.                                                                                        	BMC - LUN #0 (Channel #00h)                 
49  	04/21/2009-13:18:20  	Fan #0x31                           	CRITICAL event: Fan sensor 49 reports the sensor is in a low, critical, and going lower state.  Sensor reading: Unspecified.  Threshold value: Unspecified.                                                                                               	BMC - LUN #0 (Channel #00h)                 
50  	04/21/2009-13:18:20  	Fan #0x32                           	Warning event: Fan sensor 50 reports the sensor is in a low, but non-critical, and going lower state.  Sensor reading: Unspecified.  Threshold value: Unspecified.                                                                                        	BMC - LUN #0 (Channel #00h)                 
51  	04/21/2009-13:18:20  	Fan #0x32                           	CRITICAL event: Fan sensor 50 reports the sensor is in a low, critical, and going lower state.  Sensor reading: Unspecified.  Threshold value: Unspecified.                                                                                               	BMC - LUN #0 (Channel #00h)                 
52  	04/21/2009-13:18:20  	Fan #0x33                           	Warning event: Fan sensor 51 reports the sensor is in a low, but non-critical, and going lower state.  Sensor reading: Unspecified.  Threshold value: Unspecified.                                                                                        	BMC - LUN #0 (Channel #00h)                 
53  	04/21/2009-13:18:20  	Fan #0x33                           	CRITICAL event: Fan sensor 51 reports the sensor is in a low, critical, and going lower state.  Sensor reading: Unspecified.  Threshold value: Unspecified.                                                                                               	BMC - LUN #0 (Channel #00h)                 
54  	04/21/2009-13:18:20  	Fan #0x34                           	Warning event: Fan sensor 52 reports the sensor is in a low, but non-critical, and going lower state.  Sensor reading: Unspecified.  Threshold value: Unspecified.                                                                                        	BMC - LUN #0 (Channel #00h)                 
55  	04/21/2009-13:18:20  	Fan #0x34                           	CRITICAL event: Fan sensor 52 reports the sensor is in a low, critical, and going lower state.  Sensor reading: Unspecified.  Threshold value: Unspecified.                                                                                               	BMC - LUN #0 (Channel #00h)                 
56  	04/21/2009-13:18:20  	Fan #0x36                           	Warning event: Fan sensor 54 reports the sensor is in a low, but non-critical, and going lower state.  Sensor reading: Unspecified.  Threshold value: Unspecified.                                                                                        	BMC - LUN #0 (Channel #00h)                 
57  	04/21/2009-13:18:20  	Fan #0x36                           	CRITICAL event: Fan sensor 54 reports the sensor is in a low, critical, and going lower state.  Sensor reading: Unspecified.  Threshold value: Unspecified.                                                                                               	BMC - LUN #0 (Channel #00h)                 
58  	04/21/2009-13:18:20  	Fan #0x37                           	Warning event: Fan sensor 55 reports the sensor is in a low, but non-critical, and going lower state.  Sensor reading: Unspecified.  Threshold value: Unspecified.                                                                                        	BMC - LUN #0 (Channel #00h)                 
59  	04/21/2009-13:18:20  	Fan #0x37                           	CRITICAL event: Fan sensor 55 reports the sensor is in a low, critical, and going lower state.  Sensor reading: Unspecified.  Threshold value: Unspecified.                                                                                               	BMC - LUN #0 (Channel #00h)                 
60  	04/21/2009-13:23:40  	Processor /P1 Status (#0x60)        	Informational event: P1 Status reports the processor's presence has been detected.                                                                                                                                                                        	BMC - LUN #0 (Channel #00h)                 
61  	04/21/2009-13:23:40  	Processor /P2 Status (#0x61)        	Informational event: P2 Status reports the processor's presence has been detected.                                                                                                                                                                        	BMC - LUN #0 (Channel #00h)                 
62  	04/21/2009-13:23:48  	Power Supply /PS1 Status (#0x50)    	Informational event: PS1 Status reports the power supply's presence has been detected.                                                                                                                                                                    	BMC - LUN #0 (Channel #00h)                 
63  	04/21/2009-13:23:52  	Fan #0x31                           	Warning event: Fan sensor 49 reports the sensor is in a low, but non-critical, and going lower state.  Sensor reading: Unspecified.  Threshold value: Unspecified.                                                                                        	BMC - LUN #0 (Channel #00h)                 
64  	04/21/2009-13:23:52  	Fan #0x31                           	CRITICAL event: Fan sensor 49 reports the sensor is in a low, critical, and going lower state.  Sensor reading: Unspecified.  Threshold value: Unspecified.                                                                                               	BMC - LUN #0 (Channel #00h)                 
65  	04/21/2009-13:23:52  	Fan #0x32                           	Warning event: Fan sensor 50 reports the sensor is in a low, but non-critical, and going lower state.  Sensor reading: Unspecified.  Threshold value: Unspecified.                                                                                        	BMC - LUN #0 (Channel #00h)                 
66  	04/21/2009-13:23:52  	Fan #0x32                           	CRITICAL event: Fan sensor 50 reports the sensor is in a low, critical, and going lower state.  Sensor reading: Unspecified.  Threshold value: Unspecified.                                                                                               	BMC - LUN #0 (Channel #00h)                 
67  	04/21/2009-13:23:52  	Fan #0x33                           	Warning event: Fan sensor 51 reports the sensor is in a low, but non-critical, and going lower state.  Sensor reading: Unspecified.  Threshold value: Unspecified.                                                                                        	BMC - LUN #0 (Channel #00h)                 
68  	04/21/2009-13:23:52  	Fan #0x33                           	CRITICAL event: Fan sensor 51 reports the sensor is in a low, critical, and going lower state.  Sensor reading: Unspecified.  Threshold value: Unspecified.                                                                                               	BMC - LUN #0 (Channel #00h)                 
69  	04/21/2009-13:23:52  	Fan #0x34                           	Warning event: Fan sensor 52 reports the sensor is in a low, but non-critical, and going lower state.  Sensor reading: Unspecified.  Threshold value: Unspecified.                                                                                        	BMC - LUN #0 (Channel #00h)                 
70  	04/21/2009-13:23:52  	Fan #0x34                           	CRITICAL event: Fan sensor 52 reports the sensor is in a low, critical, and going lower state.  Sensor reading: Unspecified.  Threshold value: Unspecified.                                                                                               	BMC - LUN #0 (Channel #00h)                 
71  	04/21/2009-13:23:52  	Fan #0x36                           	Warning event: Fan sensor 54 reports the sensor is in a low, but non-critical, and going lower state.  Sensor reading: Unspecified.  Threshold value: Unspecified.                                                                                        	BMC - LUN #0 (Channel #00h)                 
72  	04/21/2009-13:23:52  	Fan #0x36                           	CRITICAL event: Fan sensor 54 reports the sensor is in a low, critical, and going lower state.  Sensor reading: Unspecified.  Threshold value: Unspecified.                                                                                               	BMC - LUN #0 (Channel #00h)                 
73  	04/21/2009-13:23:52  	Fan #0x37                           	Warning event: Fan sensor 55 reports the sensor is in a low, but non-critical, and going lower state.  Sensor reading: Unspecified.  Threshold value: Unspecified.                                                                                        	BMC - LUN #0 (Channel #00h)                 
74  	04/21/2009-13:23:52  	Fan #0x37                           	CRITICAL event: Fan sensor 55 reports the sensor is in a low, critical, and going lower state.  Sensor reading: Unspecified.  Threshold value: Unspecified.                                                                                               	BMC - LUN #0 (Channel #00h)                 
75  	04/21/2009-13:27:55  	Processor /P1 Status (#0x60)        	Informational event: P1 Status reports the processor's presence has been detected.                                                                                                                                                                        	BMC - LUN #0 (Channel #00h)                 
76  	04/21/2009-13:27:55  	Processor /P2 Status (#0x61)        	Informational event: P2 Status reports the processor's presence has been detected.                                                                                                                                                                        	BMC - LUN #0 (Channel #00h)                 
77  	04/21/2009-13:27:59  	Power Supply /PS1 Status (#0x50)    	Informational event: PS1 Status reports the power supply's presence has been detected.                                                                                                                                                                    	BMC - LUN #0 (Channel #00h)                 
78  	04/21/2009-13:27:59  	Power Supply /PS2 Status (#0x51)    	Informational event: PS2 Status reports the power supply's presence has been detected.                                                                                                                                                                    	BMC - LUN #0 (Channel #00h)                 
79  	04/21/2009-13:28:00  	Power Unit /Pwr Unit Redund (#0x02) 	Informational event: Pwr Unit Redund reports full redundancy has been regained .                                                                                                                                                                          	BMC - LUN #0 (Channel #00h)                 
80  	04/21/2009-13:28:32  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports a system boot event has occurred.                                                                                                                                                                            	BIOS (Channel #00h)                         
81  	04/21/2009-13:29:53  	Power Unit /Pwr Unit Redund (#0x02) 	Informational event: Pwr Unit Redund reports full redundancy has been regained .                                                                                                                                                                          	BMC - LUN #0 (Channel #00h)                 
82  	04/21/2009-13:29:58  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is first of two expected events from BIOS on every power on.                                                                                                                     	BIOS (Channel #00h)                         
83  	04/21/2009-13:29:58  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is second of two expected events from BIOS on every power on.                                                                                                                    	BIOS (Channel #00h)                         
84  	04/21/2009-13:30:58  	Power Unit /Pwr Unit Redund (#0x02) 	Informational event: Pwr Unit Redund reports full redundancy has been regained .                                                                                                                                                                          	BMC - LUN #0 (Channel #00h)                 
85  	04/21/2009-13:31:04  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is first of two expected events from BIOS on every power on.                                                                                                                     	BIOS (Channel #00h)                         
86  	04/21/2009-13:31:05  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is second of two expected events from BIOS on every power on.                                                                                                                    	BIOS (Channel #00h)                         
87  	04/21/2009-13:32:09  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports a system boot event has occurred.                                                                                                                                                                            	BIOS (Channel #00h)                         
88  	04/21/2009-13:34:57  	Power Unit /Pwr Unit Redund (#0x02) 	Informational event: Pwr Unit Redund reports full redundancy has been regained .                                                                                                                                                                          	BMC - LUN #0 (Channel #00h)                 
89  	04/21/2009-13:35:02  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is first of two expected events from BIOS on every power on.                                                                                                                     	BIOS (Channel #00h)                         
90  	04/21/2009-13:35:03  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is second of two expected events from BIOS on every power on.                                                                                                                    	BIOS (Channel #00h)                         
91  	04/21/2009-13:36:06  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports a system boot event has occurred.                                                                                                                                                                            	BIOS (Channel #00h)                         
92  	04/21/2009-13:36:14  	Power Unit /Pwr Unit Status (#0x01) 	Informational event: Pwr Unit Status reports the power unit is powered off or being powered down.                                                                                                                                                         	BMC - LUN #0 (Channel #00h)                 
93  	04/21/2009-13:36:14  	Button /Button (#0x09)              	Informational event: Button reports the power button has been pressed.                                                                                                                                                                                    	BMC - LUN #0 (Channel #00h)                 
94  	04/21/2009-13:36:17  	Power Supply /PS2 Status (#0x51)    	CRITICAL event: PS2 Status reports the power supply has suffered a failure.                                                                                                                                                                               	BMC - LUN #0 (Channel #00h)                 
95  	04/21/2009-13:36:17  	Power Supply /PS2 Status (#0x51)    	Warning event: PS2 Status reports the power supply's input (AC/DC) has been lost.                                                                                                                                                                         	BMC - LUN #0 (Channel #00h)                 
96  	08/26/2009-03:57:47  	Power Unit /Pwr Unit Status (#0x01) 	Informational event: Pwr Unit Status reports the power unit is powered off or being powered down.                                                                                                                                                         	BMC - LUN #0 (Channel #00h)                 
97  	08/26/2009-03:57:48  	Processor /P1 Status (#0x60)        	Informational event: P1 Status reports the processor's presence has been detected.                                                                                                                                                                        	BMC - LUN #0 (Channel #00h)                 
98  	08/26/2009-03:57:48  	Processor /P2 Status (#0x61)        	Informational event: P2 Status reports the processor's presence has been detected.                                                                                                                                                                        	BMC - LUN #0 (Channel #00h)                 
99  	08/26/2009-03:57:52  	Power Supply /PS1 Status (#0x50)    	Informational event: PS1 Status reports the power supply's presence has been detected.                                                                                                                                                                    	BMC - LUN #0 (Channel #00h)                 
100 	08/26/2009-03:57:52  	Power Supply /PS2 Status (#0x51)    	Informational event: PS2 Status reports the power supply's presence has been detected.                                                                                                                                                                    	BMC - LUN #0 (Channel #00h)                 
101 	08/26/2009-03:57:52  	Power Supply /PS2 Status (#0x51)    	CRITICAL event: PS2 Status reports the power supply has suffered a failure.                                                                                                                                                                               	BMC - LUN #0 (Channel #00h)                 
102 	08/26/2009-03:57:52  	Power Supply /PS2 Status (#0x51)    	Warning event: PS2 Status reports the power supply's input (AC/DC) has been lost.                                                                                                                                                                         	BMC - LUN #0 (Channel #00h)                 
103 	08/26/2009-03:57:53  	Power Unit /Pwr Unit Redund (#0x02) 	Warning event: Pwr Unit Redund reports redundancy has been lost .                                                                                                                                                                                         	BMC - LUN #0 (Channel #00h)                 
104 	08/26/2009-03:57:53  	Power Unit /Pwr Unit Redund (#0x02) 	Informational event: Pwr Unit Redund reports the unit has regained the minimum amount of resources needed for normal operation.                                                                                                                           	BMC - LUN #0 (Channel #00h)                 
105 	08/26/2009-03:59:06  	Power Supply /PS2 Status (#0x51)    	Informational event: PS2 Status reports the power supply has recovered from the failure.                                                                                                                                                                  	BMC - LUN #0 (Channel #00h)                 
106 	08/26/2009-03:59:06  	Power Supply /PS2 Status (#0x51)    	Informational event: PS2 Status reports the power supply's input (AC/DC) has been regained.                                                                                                                                                               	BMC - LUN #0 (Channel #00h)                 
107 	08/26/2009-03:59:07  	Power Unit /Pwr Unit Redund (#0x02) 	Informational event: Pwr Unit Redund reports full redundancy has been regained .                                                                                                                                                                          	BMC - LUN #0 (Channel #00h)                 
108 	08/26/2009-03:59:07  	Power Unit /Pwr Unit Redund (#0x02) 	Informational event: Pwr Unit Redund reports full redundancy has been regained.                                                                                                                                                                           	BMC - LUN #0 (Channel #00h)                 
109 	08/26/2009-03:59:07  	Power Unit /Pwr Unit Redund (#0x02) 	Informational event: Pwr Unit Redund reports the unit has regained the minimum amount of resources needed for normal operation.                                                                                                                           	BMC - LUN #0 (Channel #00h)                 
110 	08/26/2009-03:59:23  	Power Unit /Pwr Unit Status (#0x01) 	Informational event: Pwr Unit Status reports the power unit is powered off or being powered down.                                                                                                                                                         	BMC - LUN #0 (Channel #00h)                 
111 	08/26/2009-03:59:23  	Button /Button (#0x09)              	Informational event: Button reports the power button has been pressed.                                                                                                                                                                                    	BMC - LUN #0 (Channel #00h)                 
112 	08/26/2009-03:59:26  	Power Unit /Pwr Unit Redund (#0x02) 	Informational event: Pwr Unit Redund reports full redundancy has been regained .                                                                                                                                                                          	BMC - LUN #0 (Channel #00h)                 
113 	08/26/2009-03:59:29  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is first of two expected events from BIOS on every power on.                                                                                                                     	BIOS (Channel #00h)                         
114 	08/26/2009-03:59:30  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is second of two expected events from BIOS on every power on.                                                                                                                    	BIOS (Channel #00h)                         
115 	08/26/2009-04:00:27  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports a system boot event has occurred.                                                                                                                                                                            	BIOS (Channel #00h)                         
116 	08/26/2009-04:02:36  	Power Unit /Pwr Unit Redund (#0x02) 	Informational event: Pwr Unit Redund reports full redundancy has been regained .                                                                                                                                                                          	BMC - LUN #0 (Channel #00h)                 
117 	08/26/2009-04:02:41  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is first of two expected events from BIOS on every power on.                                                                                                                     	BIOS (Channel #00h)                         
118 	08/26/2009-04:02:41  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is second of two expected events from BIOS on every power on.                                                                                                                    	BIOS (Channel #00h)                         
119 	08/26/2009-04:08:38  	Power Unit /Pwr Unit Redund (#0x02) 	Informational event: Pwr Unit Redund reports full redundancy has been regained .                                                                                                                                                                          	BMC - LUN #0 (Channel #00h)                 
120 	08/26/2009-04:08:43  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is first of two expected events from BIOS on every power on.                                                                                                                     	BIOS (Channel #00h)                         
121 	10/13/2010-08:24:44  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is second of two expected events from BIOS on every power on.                                                                                                                    	BIOS (Channel #00h)                         
122 	10/13/2010-08:25:50  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports a system boot event has occurred.                                                                                                                                                                            	BIOS (Channel #00h)                         
123 	10/13/2010-10:01:45  	Power Unit /Pwr Unit Redund (#0x02) 	Informational event: Pwr Unit Redund reports full redundancy has been regained .                                                                                                                                                                          	BMC - LUN #0 (Channel #00h)                 
124 	10/13/2010-10:01:49  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is first of two expected events from BIOS on every power on.                                                                                                                     	BIOS (Channel #00h)                         
125 	10/13/2010-10:01:50  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is second of two expected events from BIOS on every power on.                                                                                                                    	BIOS (Channel #00h)                         
126 	10/13/2010-10:03:05  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports a system boot event has occurred.                                                                                                                                                                            	BIOS (Channel #00h)                         
127 	10/13/2010-10:03:19  	Power Unit /Pwr Unit Redund (#0x02) 	Informational event: Pwr Unit Redund reports full redundancy has been regained .                                                                                                                                                                          	BMC - LUN #0 (Channel #00h)                 
128 	10/13/2010-10:03:25  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is first of two expected events from BIOS on every power on.                                                                                                                     	BIOS (Channel #00h)                         
129 	10/13/2010-10:03:25  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is second of two expected events from BIOS on every power on.                                                                                                                    	BIOS (Channel #00h)                         
130 	10/13/2010-10:04:17  	Power Unit /Pwr Unit Redund (#0x02) 	Informational event: Pwr Unit Redund reports full redundancy has been regained .                                                                                                                                                                          	BMC - LUN #0 (Channel #00h)                 
131 	10/13/2010-10:04:22  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is first of two expected events from BIOS on every power on.                                                                                                                     	BIOS (Channel #00h)                         
132 	10/13/2010-10:04:23  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is second of two expected events from BIOS on every power on.                                                                                                                    	BIOS (Channel #00h)                         
133 	10/13/2010-10:06:08  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports a system boot event has occurred.                                                                                                                                                                            	BIOS (Channel #00h)                         
134 	10/13/2010-10:07:43  	OS Boot #0x00                       	Informational event: System Management Software states that OS Boot sensor 0 reports the boot from drive C has been completed.                                                                                                                            	System Management Software (Channel #00h)   
135 	10/13/2010-10:07:43  	OEM Event                           	Operating system bootup                                                                                                                                                                                                                                   	 OEM Event                                  
136 	10/13/2010-10:27:09  	OS Stop / Shutdown #0x00            	Warning event: System Management Software states that OS Stop/Shutdown sensor 0 reports a OS graceful shutdown.                                                                                                                                           	System Management Software (Channel #00h)   
137 	10/13/2010-10:27:09  	OEM Event                           	Operating system shutdown                                                                                                                                                                                                                                 	 OEM Event                                  
138 	10/13/2010-10:27:09  	System Event #0x83                  	Informational event: System Event sensor 131 reports Timestamp Clock Sync. Event is first of two expected events from BIOS on every power on.                                                                                                             	BIOS (Channel #00h)                         
139 	10/13/2010-10:27:09  	System Event #0x83                  	Informational event: System Event sensor 131 reports Timestamp Clock Sync. Event is first of two expected events from BIOS on every power on.                                                                                                             	BIOS (Channel #00h)                         
140 	10/13/2010-10:27:10  	Power Unit /Pwr Unit Redund (#0x02) 	Informational event: Pwr Unit Redund reports full redundancy has been regained .                                                                                                                                                                          	BMC - LUN #0 (Channel #00h)                 
141 	10/13/2010-10:27:15  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is first of two expected events from BIOS on every power on.                                                                                                                     	BIOS (Channel #00h)                         
142 	10/13/2010-10:27:16  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is second of two expected events from BIOS on every power on.                                                                                                                    	BIOS (Channel #00h)                         
143 	10/13/2010-10:28:32  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports a system boot event has occurred.                                                                                                                                                                            	BIOS (Channel #00h)                         
144 	10/13/2010-10:30:42  	Power Unit /Pwr Unit Redund (#0x02) 	Informational event: Pwr Unit Redund reports full redundancy has been regained .                                                                                                                                                                          	BMC - LUN #0 (Channel #00h)                 
145 	10/13/2010-10:30:47  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is first of two expected events from BIOS on every power on.                                                                                                                     	BIOS (Channel #00h)                         
146 	10/13/2010-10:30:47  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is second of two expected events from BIOS on every power on.                                                                                                                    	BIOS (Channel #00h)                         
147 	10/13/2010-10:32:56  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports a system boot event has occurred.                                                                                                                                                                            	BIOS (Channel #00h)                         
148 	10/13/2010-10:36:42  	Power Unit /Pwr Unit Redund (#0x02) 	Informational event: Pwr Unit Redund reports full redundancy has been regained .                                                                                                                                                                          	BMC - LUN #0 (Channel #00h)                 
149 	10/13/2010-10:36:46  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is first of two expected events from BIOS on every power on.                                                                                                                     	BIOS (Channel #00h)                         
150 	10/13/2010-10:36:47  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is second of two expected events from BIOS on every power on.                                                                                                                    	BIOS (Channel #00h)                         
151 	10/13/2010-10:38:15  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports a system boot event has occurred.                                                                                                                                                                            	BIOS (Channel #00h)                         
152 	10/13/2010-10:39:48  	OS Boot #0x00                       	Informational event: System Management Software states that OS Boot sensor 0 reports the boot from drive C has been completed.                                                                                                                            	System Management Software (Channel #00h)   
153 	10/13/2010-10:39:48  	OEM Event                           	Operating system bootup                                                                                                                                                                                                                                   	 OEM Event                                  
154 	10/13/2010-10:50:11  	OS Stop / Shutdown #0x00            	Warning event: System Management Software states that OS Stop/Shutdown sensor 0 reports a OS graceful shutdown.                                                                                                                                           	System Management Software (Channel #00h)   
155 	10/13/2010-10:50:11  	OEM Event                           	Operating system shutdown                                                                                                                                                                                                                                 	 OEM Event                                  
156 	10/13/2010-10:50:11  	System Event #0x83                  	Informational event: System Event sensor 131 reports Timestamp Clock Sync. Event is first of two expected events from BIOS on every power on.                                                                                                             	BIOS (Channel #00h)                         
157 	10/13/2010-10:50:12  	System Event #0x83                  	Informational event: System Event sensor 131 reports Timestamp Clock Sync. Event is first of two expected events from BIOS on every power on.                                                                                                             	BIOS (Channel #00h)                         
158 	10/13/2010-10:50:13  	Power Unit /Pwr Unit Redund (#0x02) 	Informational event: Pwr Unit Redund reports full redundancy has been regained .                                                                                                                                                                          	BMC - LUN #0 (Channel #00h)                 
159 	10/13/2010-10:50:18  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is first of two expected events from BIOS on every power on.                                                                                                                     	BIOS (Channel #00h)                         
160 	10/13/2010-10:50:19  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is second of two expected events from BIOS on every power on.                                                                                                                    	BIOS (Channel #00h)                         
161 	10/13/2010-10:51:18  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports a system boot event has occurred.                                                                                                                                                                            	BIOS (Channel #00h)                         
162 	10/13/2010-10:54:57  	Power Unit /Pwr Unit Redund (#0x02) 	Informational event: Pwr Unit Redund reports full redundancy has been regained .                                                                                                                                                                          	BMC - LUN #0 (Channel #00h)                 
163 	10/13/2010-10:55:01  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is first of two expected events from BIOS on every power on.                                                                                                                     	BIOS (Channel #00h)                         
164 	10/13/2010-10:55:02  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is second of two expected events from BIOS on every power on.                                                                                                                    	BIOS (Channel #00h)                         
165 	10/13/2010-10:56:26  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports a system boot event has occurred.                                                                                                                                                                            	BIOS (Channel #00h)                         
166 	10/13/2010-10:56:45  	Power Unit /Pwr Unit Redund (#0x02) 	Informational event: Pwr Unit Redund reports full redundancy has been regained .                                                                                                                                                                          	BMC - LUN #0 (Channel #00h)                 
167 	10/13/2010-10:56:50  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is first of two expected events from BIOS on every power on.                                                                                                                     	BIOS (Channel #00h)                         
168 	10/13/2010-10:56:51  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is second of two expected events from BIOS on every power on.                                                                                                                    	BIOS (Channel #00h)                         
169 	10/13/2010-10:57:53  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports a system boot event has occurred.                                                                                                                                                                            	BIOS (Channel #00h)                         
170 	10/13/2010-10:58:04  	Power Unit /Pwr Unit Redund (#0x02) 	Informational event: Pwr Unit Redund reports full redundancy has been regained .                                                                                                                                                                          	BMC - LUN #0 (Channel #00h)                 
171 	10/13/2010-10:58:09  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is first of two expected events from BIOS on every power on.                                                                                                                     	BIOS (Channel #00h)                         
172 	10/13/2010-10:58:10  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is second of two expected events from BIOS on every power on.                                                                                                                    	BIOS (Channel #00h)                         
173 	10/13/2010-10:59:26  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports a system boot event has occurred.                                                                                                                                                                            	BIOS (Channel #00h)                         
174 	10/13/2010-11:01:00  	OS Boot #0x00                       	Informational event: System Management Software states that OS Boot sensor 0 reports the boot from drive C has been completed.                                                                                                                            	System Management Software (Channel #00h)   
175 	10/13/2010-11:01:00  	OEM Event                           	Operating system bootup                                                                                                                                                                                                                                   	 OEM Event                                  
176 	10/13/2010-11:25:39  	OS Stop / Shutdown #0x00            	Warning event: System Management Software states that OS Stop/Shutdown sensor 0 reports a OS graceful shutdown.                                                                                                                                           	System Management Software (Channel #00h)   
177 	10/13/2010-11:25:39  	OEM Event                           	Operating system shutdown                                                                                                                                                                                                                                 	 OEM Event                                  
178 	10/13/2010-11:25:39  	System Event #0x83                  	Informational event: System Event sensor 131 reports Timestamp Clock Sync. Event is first of two expected events from BIOS on every power on.                                                                                                             	BIOS (Channel #00h)                         
179 	10/13/2010-11:25:40  	System Event #0x83                  	Informational event: System Event sensor 131 reports Timestamp Clock Sync. Event is first of two expected events from BIOS on every power on.                                                                                                             	BIOS (Channel #00h)                         
180 	10/13/2010-11:25:40  	Power Unit /Pwr Unit Redund (#0x02) 	Informational event: Pwr Unit Redund reports full redundancy has been regained .                                                                                                                                                                          	BMC - LUN #0 (Channel #00h)                 
181 	10/13/2010-11:25:45  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is first of two expected events from BIOS on every power on.                                                                                                                     	BIOS (Channel #00h)                         
182 	10/13/2010-11:25:46  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is second of two expected events from BIOS on every power on.                                                                                                                    	BIOS (Channel #00h)                         
183 	10/13/2010-11:26:57  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports a system boot event has occurred.                                                                                                                                                                            	BIOS (Channel #00h)                         
184 	10/13/2010-11:27:14  	Power Unit /Pwr Unit Redund (#0x02) 	Informational event: Pwr Unit Redund reports full redundancy has been regained .                                                                                                                                                                          	BMC - LUN #0 (Channel #00h)                 
185 	10/13/2010-11:27:19  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is first of two expected events from BIOS on every power on.                                                                                                                     	BIOS (Channel #00h)                         
186 	10/13/2010-11:27:19  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is second of two expected events from BIOS on every power on.                                                                                                                    	BIOS (Channel #00h)                         
187 	10/13/2010-11:28:35  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports a system boot event has occurred.                                                                                                                                                                            	BIOS (Channel #00h)                         
188 	10/13/2010-11:28:43  	Power Unit /Pwr Unit Redund (#0x02) 	Informational event: Pwr Unit Redund reports full redundancy has been regained .                                                                                                                                                                          	BMC - LUN #0 (Channel #00h)                 
189 	10/13/2010-11:28:48  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is first of two expected events from BIOS on every power on.                                                                                                                     	BIOS (Channel #00h)                         
190 	10/13/2010-11:28:49  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is second of two expected events from BIOS on every power on.                                                                                                                    	BIOS (Channel #00h)                         
191 	10/13/2010-11:29:57  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports a system boot event has occurred.                                                                                                                                                                            	BIOS (Channel #00h)                         
192 	10/13/2010-11:32:55  	Power Unit /Pwr Unit Redund (#0x02) 	Informational event: Pwr Unit Redund reports full redundancy has been regained .                                                                                                                                                                          	BMC - LUN #0 (Channel #00h)                 
193 	10/13/2010-11:33:01  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is first of two expected events from BIOS on every power on.                                                                                                                     	BIOS (Channel #00h)                         
194 	10/13/2010-11:33:01  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is second of two expected events from BIOS on every power on.                                                                                                                    	BIOS (Channel #00h)                         
195 	10/13/2010-11:34:13  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports a system boot event has occurred.                                                                                                                                                                            	BIOS (Channel #00h)                         
196 	10/13/2010-11:35:46  	OS Boot #0x00                       	Informational event: System Management Software states that OS Boot sensor 0 reports the boot from drive C has been completed.                                                                                                                            	System Management Software (Channel #00h)   
197 	10/13/2010-11:35:46  	OEM Event                           	Operating system bootup                                                                                                                                                                                                                                   	 OEM Event                                  
198 	10/13/2010-14:41:02  	OS Stop / Shutdown #0x00            	Warning event: System Management Software states that OS Stop/Shutdown sensor 0 reports a OS graceful shutdown.                                                                                                                                           	System Management Software (Channel #00h)   
199 	10/13/2010-14:41:02  	OEM Event                           	Operating system shutdown                                                                                                                                                                                                                                 	 OEM Event                                  
200 	10/13/2010-14:41:03  	System Event #0x83                  	Informational event: System Event sensor 131 reports Timestamp Clock Sync. Event is first of two expected events from BIOS on every power on.                                                                                                             	BIOS (Channel #00h)                         
201 	10/13/2010-14:41:03  	System Event #0x83                  	Informational event: System Event sensor 131 reports Timestamp Clock Sync. Event is first of two expected events from BIOS on every power on.                                                                                                             	BIOS (Channel #00h)                         
202 	10/13/2010-14:41:04  	Power Unit /Pwr Unit Redund (#0x02) 	Informational event: Pwr Unit Redund reports full redundancy has been regained .                                                                                                                                                                          	BMC - LUN #0 (Channel #00h)                 
203 	10/13/2010-14:41:09  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is first of two expected events from BIOS on every power on.                                                                                                                     	BIOS (Channel #00h)                         
204 	10/13/2010-14:41:10  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is second of two expected events from BIOS on every power on.                                                                                                                    	BIOS (Channel #00h)                         
205 	10/13/2010-14:59:10  	Power Unit /Pwr Unit Redund (#0x02) 	Informational event: Pwr Unit Redund reports full redundancy has been regained .                                                                                                                                                                          	BMC - LUN #0 (Channel #00h)                 
206 	10/13/2010-14:59:15  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is first of two expected events from BIOS on every power on.                                                                                                                     	BIOS (Channel #00h)                         
207 	10/13/2010-14:59:16  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is second of two expected events from BIOS on every power on.                                                                                                                    	BIOS (Channel #00h)                         
208 	10/13/2010-15:00:21  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports a system boot event has occurred.                                                                                                                                                                            	BIOS (Channel #00h)                         
209 	10/13/2010-15:00:27  	Power Unit /Pwr Unit Redund (#0x02) 	Informational event: Pwr Unit Redund reports full redundancy has been regained .                                                                                                                                                                          	BMC - LUN #0 (Channel #00h)                 
210 	10/13/2010-15:00:33  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is first of two expected events from BIOS on every power on.                                                                                                                     	BIOS (Channel #00h)                         
211 	10/13/2010-15:00:33  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is second of two expected events from BIOS on every power on.                                                                                                                    	BIOS (Channel #00h)                         
212 	10/13/2010-15:02:15  	Power Unit /Pwr Unit Redund (#0x02) 	Informational event: Pwr Unit Redund reports full redundancy has been regained .                                                                                                                                                                          	BMC - LUN #0 (Channel #00h)                 
213 	10/13/2010-15:02:20  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is first of two expected events from BIOS on every power on.                                                                                                                     	BIOS (Channel #00h)                         
214 	10/13/2010-15:02:21  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is second of two expected events from BIOS on every power on.                                                                                                                    	BIOS (Channel #00h)                         
215 	10/13/2010-15:04:42  	Power Unit /Pwr Unit Redund (#0x02) 	Informational event: Pwr Unit Redund reports full redundancy has been regained .                                                                                                                                                                          	BMC - LUN #0 (Channel #00h)                 
216 	10/13/2010-15:04:47  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is first of two expected events from BIOS on every power on.                                                                                                                     	BIOS (Channel #00h)                         
217 	10/13/2010-15:04:48  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is second of two expected events from BIOS on every power on.                                                                                                                    	BIOS (Channel #00h)                         
218 	10/13/2010-15:06:15  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports a system boot event has occurred.                                                                                                                                                                            	BIOS (Channel #00h)                         
219 	10/13/2010-15:07:50  	OS Boot #0x00                       	Informational event: System Management Software states that OS Boot sensor 0 reports the boot from drive C has been completed.                                                                                                                            	System Management Software (Channel #00h)   
220 	10/13/2010-15:07:50  	OEM Event                           	Operating system bootup                                                                                                                                                                                                                                   	 OEM Event                                  
221 	10/13/2010-15:17:58  	System Event #0x83                  	Informational event: System Event sensor 131 reports Timestamp Clock Sync. Event is first of two expected events from BIOS on every power on.                                                                                                             	BIOS (Channel #00h)                         
222 	10/13/2010-15:18:00  	System Event #0x83                  	Informational event: System Event sensor 131 reports Timestamp Clock Sync. Event is first of two expected events from BIOS on every power on.                                                                                                             	BIOS (Channel #00h)                         
223 	10/13/2010-15:18:01  	Power Unit /Pwr Unit Redund (#0x02) 	Informational event: Pwr Unit Redund reports full redundancy has been regained .                                                                                                                                                                          	BMC - LUN #0 (Channel #00h)                 
224 	10/13/2010-15:18:06  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is first of two expected events from BIOS on every power on.                                                                                                                     	BIOS (Channel #00h)                         
225 	10/13/2010-15:18:06  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is second of two expected events from BIOS on every power on.                                                                                                                    	BIOS (Channel #00h)                         
226 	10/13/2010-15:19:26  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports a system boot event has occurred.                                                                                                                                                                            	BIOS (Channel #00h)                         
227 	10/13/2010-15:19:53  	OS Boot #0x00                       	Informational event: System Management Software states that OS Boot sensor 0 reports the boot from drive C has been completed.                                                                                                                            	System Management Software (Channel #00h)   
228 	10/13/2010-15:19:53  	OEM Event                           	Operating system bootup                                                                                                                                                                                                                                   	 OEM Event                                  
229 	10/13/2010-15:22:42  	System Event #0x83                  	Informational event: System Event sensor 131 reports Timestamp Clock Sync. Event is first of two expected events from BIOS on every power on.                                                                                                             	BIOS (Channel #00h)                         
230 	10/13/2010-15:24:09  	OS Stop / Shutdown #0x00            	Warning event: System Management Software states that OS Stop/Shutdown sensor 0 reports a OS graceful shutdown.                                                                                                                                           	System Management Software (Channel #00h)   
231 	10/13/2010-15:24:09  	OEM Event                           	Operating system shutdown                                                                                                                                                                                                                                 	 OEM Event                                  
232 	10/13/2010-15:24:13  	System Event #0x83                  	Informational event: System Event sensor 131 reports Timestamp Clock Sync. Event is first of two expected events from BIOS on every power on.                                                                                                             	BIOS (Channel #00h)                         
233 	10/13/2010-15:24:15  	System Event #0x83                  	Informational event: System Event sensor 131 reports Timestamp Clock Sync. Event is first of two expected events from BIOS on every power on.                                                                                                             	BIOS (Channel #00h)                         
234 	10/13/2010-15:24:16  	Power Unit /Pwr Unit Redund (#0x02) 	Informational event: Pwr Unit Redund reports full redundancy has been regained .                                                                                                                                                                          	BMC - LUN #0 (Channel #00h)                 
235 	10/13/2010-15:24:21  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is first of two expected events from BIOS on every power on.                                                                                                                     	BIOS (Channel #00h)                         
236 	10/13/2010-15:24:21  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is second of two expected events from BIOS on every power on.                                                                                                                    	BIOS (Channel #00h)                         
237 	10/13/2010-15:25:38  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports a system boot event has occurred.                                                                                                                                                                            	BIOS (Channel #00h)                         
238 	10/13/2010-15:26:04  	OS Boot #0x00                       	Informational event: System Management Software states that OS Boot sensor 0 reports the boot from drive C has been completed.                                                                                                                            	System Management Software (Channel #00h)   
239 	10/13/2010-15:26:04  	OEM Event                           	Operating system bootup                                                                                                                                                                                                                                   	 OEM Event                                  
240 	10/13/2010-15:46:44  	Button /Button (#0x09)              	Informational event: Button reports the power button has been pressed.                                                                                                                                                                                    	BMC - LUN #0 (Channel #00h)                 
241 	10/13/2010-15:47:06  	OS Stop / Shutdown #0x00            	Warning event: System Management Software states that OS Stop/Shutdown sensor 0 reports a OS graceful shutdown.                                                                                                                                           	System Management Software (Channel #00h)   
242 	10/13/2010-15:47:06  	OEM Event                           	Operating system shutdown                                                                                                                                                                                                                                 	 OEM Event                                  
243 	10/13/2010-15:47:10  	System Event #0x83                  	Informational event: System Event sensor 131 reports Timestamp Clock Sync. Event is first of two expected events from BIOS on every power on.                                                                                                             	BIOS (Channel #00h)                         
244 	10/13/2010-15:47:12  	System Event #0x83                  	Informational event: System Event sensor 131 reports Timestamp Clock Sync. Event is first of two expected events from BIOS on every power on.                                                                                                             	BIOS (Channel #00h)                         
245 	10/13/2010-15:47:13  	Power Unit /Pwr Unit Status (#0x01) 	Informational event: Pwr Unit Status reports the power unit is powered off or being powered down.                                                                                                                                                         	BMC - LUN #0 (Channel #00h)                 
246 	10/13/2010-15:47:48  	Power Unit /Pwr Unit Status (#0x01) 	Informational event: Pwr Unit Status reports the power unit is powered off or being powered down.                                                                                                                                                         	BMC - LUN #0 (Channel #00h)                 
247 	10/13/2010-15:47:48  	Button /Button (#0x09)              	Informational event: Button reports the power button has been pressed.                                                                                                                                                                                    	BMC - LUN #0 (Channel #00h)                 
248 	10/13/2010-15:47:51  	Power Unit /Pwr Unit Redund (#0x02) 	Informational event: Pwr Unit Redund reports full redundancy has been regained .                                                                                                                                                                          	BMC - LUN #0 (Channel #00h)                 
249 	10/13/2010-15:47:54  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is first of two expected events from BIOS on every power on.                                                                                                                     	BIOS (Channel #00h)                         
250 	10/13/2010-15:47:55  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is second of two expected events from BIOS on every power on.                                                                                                                    	BIOS (Channel #00h)                         
251 	10/13/2010-15:49:10  	Power Unit /Pwr Unit Redund (#0x02) 	Informational event: Pwr Unit Redund reports full redundancy has been regained .                                                                                                                                                                          	BMC - LUN #0 (Channel #00h)                 
252 	10/13/2010-15:49:15  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is first of two expected events from BIOS on every power on.                                                                                                                     	BIOS (Channel #00h)                         
253 	10/13/2010-15:49:16  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is second of two expected events from BIOS on every power on.                                                                                                                    	BIOS (Channel #00h)                         
254 	10/13/2010-15:50:36  	Power Unit /Pwr Unit Redund (#0x02) 	Informational event: Pwr Unit Redund reports full redundancy has been regained .                                                                                                                                                                          	BMC - LUN #0 (Channel #00h)                 
255 	10/13/2010-15:50:41  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is first of two expected events from BIOS on every power on.                                                                                                                     	BIOS (Channel #00h)                         
256 	10/13/2010-15:50:42  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is second of two expected events from BIOS on every power on.                                                                                                                    	BIOS (Channel #00h)                         
257 	10/13/2010-15:52:43  	Power Unit /Pwr Unit Redund (#0x02) 	Informational event: Pwr Unit Redund reports full redundancy has been regained .                                                                                                                                                                          	BMC - LUN #0 (Channel #00h)                 
258 	10/13/2010-15:52:48  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is first of two expected events from BIOS on every power on.                                                                                                                     	BIOS (Channel #00h)                         
259 	10/13/2010-15:52:49  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is second of two expected events from BIOS on every power on.                                                                                                                    	BIOS (Channel #00h)                         
260 	10/13/2010-15:54:27  	Power Unit /Pwr Unit Redund (#0x02) 	Informational event: Pwr Unit Redund reports full redundancy has been regained .                                                                                                                                                                          	BMC - LUN #0 (Channel #00h)                 
261 	10/13/2010-15:54:33  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is first of two expected events from BIOS on every power on.                                                                                                                     	BIOS (Channel #00h)                         
262 	10/13/2010-15:54:33  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is second of two expected events from BIOS on every power on.                                                                                                                    	BIOS (Channel #00h)                         
263 	10/13/2010-15:56:02  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports a system boot event has occurred.                                                                                                                                                                            	BIOS (Channel #00h)                         
264 	10/13/2010-16:09:12  	Power Unit /Pwr Unit Status (#0x01) 	Informational event: Pwr Unit Status reports the power unit is powered off or being powered down.                                                                                                                                                         	BMC - LUN #0 (Channel #00h)                 
265 	10/13/2010-16:09:12  	Button /Button (#0x09)              	Informational event: Button reports the power button has been pressed.                                                                                                                                                                                    	BMC - LUN #0 (Channel #00h)                 
266 	11/03/2010-15:01:26  	Processor /P1 Status (#0x60)        	Informational event: P1 Status reports the processor's presence has been detected.                                                                                                                                                                        	BMC - LUN #0 (Channel #00h)                 
267 	11/03/2010-15:01:26  	Processor /P2 Status (#0x61)        	Informational event: P2 Status reports the processor's presence has been detected.                                                                                                                                                                        	BMC - LUN #0 (Channel #00h)                 
268 	11/03/2010-15:01:30  	Power Supply /PS1 Status (#0x50)    	Informational event: PS1 Status reports the power supply's presence has been detected.                                                                                                                                                                    	BMC - LUN #0 (Channel #00h)                 
269 	11/03/2010-15:01:30  	Power Supply /PS2 Status (#0x51)    	Informational event: PS2 Status reports the power supply's presence has been detected.                                                                                                                                                                    	BMC - LUN #0 (Channel #00h)                 
270 	11/03/2010-15:01:31  	Power Unit /Pwr Unit Redund (#0x02) 	Informational event: Pwr Unit Redund reports full redundancy has been regained .                                                                                                                                                                          	BMC - LUN #0 (Channel #00h)                 
271 	11/03/2010-15:01:38  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is first of two expected events from BIOS on every power on.                                                                                                                     	BIOS (Channel #00h)                         
272 	11/03/2010-15:01:38  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is second of two expected events from BIOS on every power on.                                                                                                                    	BIOS (Channel #00h)                         
273 	11/03/2010-15:03:08  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports a system boot event has occurred.                                                                                                                                                                            	BIOS (Channel #00h)                         
274 	11/03/2010-15:04:38  	OS Boot #0x00                       	Informational event: System Management Software states that OS Boot sensor 0 reports the boot from drive C has been completed.                                                                                                                            	System Management Software (Channel #00h)   
275 	11/03/2010-15:04:38  	OEM Event                           	Operating system bootup                                                                                                                                                                                                                                   	 OEM Event                                  
276 	11/03/2010-15:14:21  	System Event #0x83                  	Informational event: System Event sensor 131 reports Timestamp Clock Sync. Event is first of two expected events from BIOS on every power on.                                                                                                             	BIOS (Channel #00h)                         
277 	11/03/2010-15:14:23  	System Event #0x83                  	Informational event: System Event sensor 131 reports Timestamp Clock Sync. Event is first of two expected events from BIOS on every power on.                                                                                                             	BIOS (Channel #00h)                         
278 	11/03/2010-15:14:23  	Power Unit /Pwr Unit Redund (#0x02) 	Informational event: Pwr Unit Redund reports full redundancy has been regained .                                                                                                                                                                          	BMC - LUN #0 (Channel #00h)                 
279 	11/03/2010-15:14:28  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is first of two expected events from BIOS on every power on.                                                                                                                     	BIOS (Channel #00h)                         
280 	11/03/2010-15:14:29  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is second of two expected events from BIOS on every power on.                                                                                                                    	BIOS (Channel #00h)                         
281 	11/03/2010-15:16:24  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports a system boot event has occurred.                                                                                                                                                                            	BIOS (Channel #00h)                         
282 	11/03/2010-15:16:56  	OS Boot #0x00                       	Informational event: System Management Software states that OS Boot sensor 0 reports the boot from drive C has been completed.                                                                                                                            	System Management Software (Channel #00h)   
283 	11/03/2010-15:16:56  	OEM Event                           	Operating system bootup                                                                                                                                                                                                                                   	 OEM Event                                  
284 	11/03/2010-15:19:30  	System Event #0x83                  	Informational event: System Event sensor 131 reports Timestamp Clock Sync. Event is first of two expected events from BIOS on every power on.                                                                                                             	BIOS (Channel #00h)                         
285 	11/03/2010-15:23:13  	Button /Button (#0x09)              	Informational event: Button reports the power button has been pressed.                                                                                                                                                                                    	BMC - LUN #0 (Channel #00h)                 
286 	11/03/2010-15:23:43  	Button /Button (#0x09)              	Informational event: Button reports the power button has been pressed.                                                                                                                                                                                    	BMC - LUN #0 (Channel #00h)                 
287 	11/03/2010-15:23:52  	Button /Button (#0x09)              	Informational event: Button reports the power button has been pressed.                                                                                                                                                                                    	BMC - LUN #0 (Channel #00h)                 
288 	11/03/2010-15:23:56  	Power Unit /Pwr Unit Status (#0x01) 	Informational event: Pwr Unit Status reports the power unit is powered off or being powered down.                                                                                                                                                         	BMC - LUN #0 (Channel #00h)                 
289 	11/03/2010-15:23:57  	Button /Button (#0x09)              	Informational event: Button reports the power button has been pressed.                                                                                                                                                                                    	BMC - LUN #0 (Channel #00h)                 
290 	11/03/2010-15:23:58  	Power Unit /Pwr Unit Status (#0x01) 	Informational event: Pwr Unit Status reports the power unit is powered off or being powered down.                                                                                                                                                         	BMC - LUN #0 (Channel #00h)                 
291 	11/03/2010-15:24:01  	Power Unit /Pwr Unit Redund (#0x02) 	Informational event: Pwr Unit Redund reports full redundancy has been regained .                                                                                                                                                                          	BMC - LUN #0 (Channel #00h)                 
292 	11/03/2010-15:24:04  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is first of two expected events from BIOS on every power on.                                                                                                                     	BIOS (Channel #00h)                         
293 	11/03/2010-15:24:05  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is second of two expected events from BIOS on every power on.                                                                                                                    	BIOS (Channel #00h)                         
294 	11/03/2010-15:25:27  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports a system boot event has occurred.                                                                                                                                                                            	BIOS (Channel #00h)                         
295 	11/03/2010-15:26:02  	OS Boot #0x00                       	Informational event: System Management Software states that OS Boot sensor 0 reports the boot from drive C has been completed.                                                                                                                            	System Management Software (Channel #00h)   
296 	11/03/2010-15:26:02  	OEM Event                           	Operating system bootup                                                                                                                                                                                                                                   	 OEM Event                                  
297 	11/03/2010-15:45:15  	OS Stop / Shutdown #0x00            	Warning event: System Management Software states that OS Stop/Shutdown sensor 0 reports a OS graceful shutdown.                                                                                                                                           	System Management Software (Channel #00h)   
298 	11/03/2010-15:45:15  	OEM Event                           	Operating system shutdown                                                                                                                                                                                                                                 	 OEM Event                                  
299 	11/03/2010-15:45:27  	System Event #0x83                  	Informational event: System Event sensor 131 reports Timestamp Clock Sync. Event is first of two expected events from BIOS on every power on.                                                                                                             	BIOS (Channel #00h)                         
300 	11/03/2010-15:45:29  	System Event #0x83                  	Informational event: System Event sensor 131 reports Timestamp Clock Sync. Event is first of two expected events from BIOS on every power on.                                                                                                             	BIOS (Channel #00h)                         
301 	11/03/2010-15:45:31  	Power Unit /Pwr Unit Status (#0x01) 	Informational event: Pwr Unit Status reports the power unit is powered off or being powered down.                                                                                                                                                         	BMC - LUN #0 (Channel #00h)                 
302 	11/11/2010-10:40:54  	Processor /P1 Status (#0x60)        	Informational event: P1 Status reports the processor's presence has been detected.                                                                                                                                                                        	BMC - LUN #0 (Channel #00h)                 
303 	11/11/2010-10:40:54  	Processor /P2 Status (#0x61)        	Informational event: P2 Status reports the processor's presence has been detected.                                                                                                                                                                        	BMC - LUN #0 (Channel #00h)                 
304 	11/11/2010-10:40:58  	Power Supply /PS1 Status (#0x50)    	Informational event: PS1 Status reports the power supply's presence has been detected.                                                                                                                                                                    	BMC - LUN #0 (Channel #00h)                 
305 	11/11/2010-10:40:58  	Power Supply /PS2 Status (#0x51)    	Informational event: PS2 Status reports the power supply's presence has been detected.                                                                                                                                                                    	BMC - LUN #0 (Channel #00h)                 
306 	11/11/2010-10:40:58  	Power Supply /PS2 Status (#0x51)    	CRITICAL event: PS2 Status reports the power supply has suffered a failure.                                                                                                                                                                               	BMC - LUN #0 (Channel #00h)                 
307 	11/11/2010-10:40:58  	Power Supply /PS2 Status (#0x51)    	Warning event: PS2 Status reports the power supply's input (AC/DC) has been lost.                                                                                                                                                                         	BMC - LUN #0 (Channel #00h)                 
308 	11/11/2010-10:40:59  	Power Unit /Pwr Unit Redund (#0x02) 	Warning event: Pwr Unit Redund reports redundancy has been lost .                                                                                                                                                                                         	BMC - LUN #0 (Channel #00h)                 
309 	11/11/2010-10:40:59  	Power Unit /Pwr Unit Redund (#0x02) 	Informational event: Pwr Unit Redund reports the unit has regained the minimum amount of resources needed for normal operation.                                                                                                                           	BMC - LUN #0 (Channel #00h)                 
310 	11/11/2010-10:40:59  	Power Supply /PS2 Status (#0x51)    	Informational event: PS2 Status reports the power supply has recovered from the failure.                                                                                                                                                                  	BMC - LUN #0 (Channel #00h)                 
311 	11/11/2010-10:40:59  	Power Supply /PS2 Status (#0x51)    	Informational event: PS2 Status reports the power supply's input (AC/DC) has been regained.                                                                                                                                                               	BMC - LUN #0 (Channel #00h)                 
312 	11/11/2010-10:41:00  	Power Unit /Pwr Unit Redund (#0x02) 	Informational event: Pwr Unit Redund reports full redundancy has been regained .                                                                                                                                                                          	BMC - LUN #0 (Channel #00h)                 
313 	11/11/2010-10:41:00  	Power Unit /Pwr Unit Redund (#0x02) 	Informational event: Pwr Unit Redund reports full redundancy has been regained.                                                                                                                                                                           	BMC - LUN #0 (Channel #00h)                 
314 	11/11/2010-10:41:00  	Power Unit /Pwr Unit Redund (#0x02) 	Informational event: Pwr Unit Redund reports the unit has regained the minimum amount of resources needed for normal operation.                                                                                                                           	BMC - LUN #0 (Channel #00h)                 
315 	11/11/2010-10:41:08  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is first of two expected events from BIOS on every power on.                                                                                                                     	BIOS (Channel #00h)                         
316 	11/11/2010-10:41:08  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is second of two expected events from BIOS on every power on.                                                                                                                    	BIOS (Channel #00h)                         
317 	11/11/2010-10:42:27  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports a system boot event has occurred.                                                                                                                                                                            	BIOS (Channel #00h)                         
318 	11/11/2010-10:42:56  	OS Boot #0x00                       	Informational event: System Management Software states that OS Boot sensor 0 reports the boot from drive C has been completed.                                                                                                                            	System Management Software (Channel #00h)   
319 	11/11/2010-10:42:56  	OEM Event                           	Operating system bootup                                                                                                                                                                                                                                   	 OEM Event                                  
320 	11/11/2010-10:46:50  	OS Stop / Shutdown #0x00            	Warning event: System Management Software states that OS Stop/Shutdown sensor 0 reports a OS graceful shutdown.                                                                                                                                           	System Management Software (Channel #00h)   
321 	11/11/2010-10:46:50  	OEM Event                           	Operating system shutdown                                                                                                                                                                                                                                 	 OEM Event                                  
322 	11/11/2010-10:46:53  	System Event #0x83                  	Informational event: System Event sensor 131 reports Timestamp Clock Sync. Event is first of two expected events from BIOS on every power on.                                                                                                             	BIOS (Channel #00h)                         
323 	11/11/2010-10:46:56  	System Event #0x83                  	Informational event: System Event sensor 131 reports Timestamp Clock Sync. Event is first of two expected events from BIOS on every power on.                                                                                                             	BIOS (Channel #00h)                         
324 	11/11/2010-10:46:56  	Power Unit /Pwr Unit Status (#0x01) 	Informational event: Pwr Unit Status reports the power unit is powered off or being powered down.                                                                                                                                                         	BMC - LUN #0 (Channel #00h)                 
325 	11/12/2010-10:20:25  	Button /Button (#0x09)              	Informational event: Button reports the power button has been pressed.                                                                                                                                                                                    	BMC - LUN #0 (Channel #00h)                 
326 	11/12/2010-10:20:26  	Processor /P1 Status (#0x60)        	Informational event: P1 Status reports the processor's presence has been detected.                                                                                                                                                                        	BMC - LUN #0 (Channel #00h)                 
327 	11/12/2010-10:20:26  	Processor /P2 Status (#0x61)        	Informational event: P2 Status reports the processor's presence has been detected.                                                                                                                                                                        	BMC - LUN #0 (Channel #00h)                 
328 	11/12/2010-10:20:28  	Power Unit /Pwr Unit Status (#0x01) 	Informational event: Pwr Unit Status reports the power unit is powered off or being powered down.                                                                                                                                                         	BMC - LUN #0 (Channel #00h)                 
329 	11/12/2010-10:20:28  	Power Supply /PS1 Status (#0x50)    	Informational event: PS1 Status reports the power supply's presence has been detected.                                                                                                                                                                    	BMC - LUN #0 (Channel #00h)                 
330 	11/12/2010-10:20:28  	Power Supply /PS2 Status (#0x51)    	Informational event: PS2 Status reports the power supply's presence has been detected.                                                                                                                                                                    	BMC - LUN #0 (Channel #00h)                 
331 	11/12/2010-10:20:28  	Power Supply /PS2 Status (#0x51)    	CRITICAL event: PS2 Status reports the power supply has suffered a failure.                                                                                                                                                                               	BMC - LUN #0 (Channel #00h)                 
332 	11/12/2010-10:20:28  	Power Supply /PS2 Status (#0x51)    	Warning event: PS2 Status reports the power supply's input (AC/DC) has been lost.                                                                                                                                                                         	BMC - LUN #0 (Channel #00h)                 
333 	11/12/2010-10:20:29  	Power Unit /Pwr Unit Redund (#0x02) 	Warning event: Pwr Unit Redund reports redundancy has been lost .                                                                                                                                                                                         	BMC - LUN #0 (Channel #00h)                 
334 	11/12/2010-10:20:29  	Power Unit /Pwr Unit Redund (#0x02) 	Informational event: Pwr Unit Redund reports the unit has regained the minimum amount of resources needed for normal operation.                                                                                                                           	BMC - LUN #0 (Channel #00h)                 
335 	11/12/2010-10:20:29  	Power Supply /PS2 Status (#0x51)    	Informational event: PS2 Status reports the power supply has recovered from the failure.                                                                                                                                                                  	BMC - LUN #0 (Channel #00h)                 
336 	11/12/2010-10:20:29  	Power Supply /PS2 Status (#0x51)    	Informational event: PS2 Status reports the power supply's input (AC/DC) has been regained.                                                                                                                                                               	BMC - LUN #0 (Channel #00h)                 
337 	11/12/2010-10:20:30  	Power Unit /Pwr Unit Redund (#0x02) 	Informational event: Pwr Unit Redund reports full redundancy has been regained .                                                                                                                                                                          	BMC - LUN #0 (Channel #00h)                 
338 	11/12/2010-10:20:30  	Power Unit /Pwr Unit Redund (#0x02) 	Informational event: Pwr Unit Redund reports full redundancy has been regained.                                                                                                                                                                           	BMC - LUN #0 (Channel #00h)                 
339 	11/12/2010-10:20:30  	Power Unit /Pwr Unit Redund (#0x02) 	Informational event: Pwr Unit Redund reports the unit has regained the minimum amount of resources needed for normal operation.                                                                                                                           	BMC - LUN #0 (Channel #00h)                 
340 	11/12/2010-10:20:35  	Power Supply /PS1 Status (#0x50)    	CRITICAL event: PS1 Status reports the power supply has suffered a failure.                                                                                                                                                                               	BMC - LUN #0 (Channel #00h)                 
341 	11/12/2010-10:20:35  	Power Supply /PS1 Status (#0x50)    	Warning event: PS1 Status reports the power supply's input (AC/DC) has been lost.                                                                                                                                                                         	BMC - LUN #0 (Channel #00h)                 
342 	11/24/2010-15:25:50  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is first of two expected events from BIOS on every power on.                                                                                                                     	BIOS (Channel #00h)                         
343 	11/24/2010-15:25:51  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is second of two expected events from BIOS on every power on.                                                                                                                    	BIOS (Channel #00h)                         
344 	11/24/2010-15:25:51  	Processor /P1 Status (#0x60)        	Informational event: P1 Status reports the processor's presence has been detected.                                                                                                                                                                        	BMC - LUN #0 (Channel #00h)                 
345 	11/24/2010-15:25:52  	Processor /P2 Status (#0x61)        	Informational event: P2 Status reports the processor's presence has been detected.                                                                                                                                                                        	BMC - LUN #0 (Channel #00h)                 
346 	11/24/2010-15:25:54  	Power Supply /PS1 Status (#0x50)    	Informational event: PS1 Status reports the power supply's presence has been detected.                                                                                                                                                                    	BMC - LUN #0 (Channel #00h)                 
347 	11/24/2010-15:25:54  	Power Supply /PS1 Status (#0x50)    	CRITICAL event: PS1 Status reports the power supply has suffered a failure.                                                                                                                                                                               	BMC - LUN #0 (Channel #00h)                 
348 	11/24/2010-15:25:54  	Power Supply /PS1 Status (#0x50)    	Warning event: PS1 Status reports the power supply's input (AC/DC) has been lost.                                                                                                                                                                         	BMC - LUN #0 (Channel #00h)                 
349 	11/24/2010-15:25:54  	Power Supply /PS2 Status (#0x51)    	Informational event: PS2 Status reports the power supply's presence has been detected.                                                                                                                                                                    	BMC - LUN #0 (Channel #00h)                 
350 	11/24/2010-15:25:55  	Power Unit /Pwr Unit Redund (#0x02) 	Warning event: Pwr Unit Redund reports redundancy has been lost .                                                                                                                                                                                         	BMC - LUN #0 (Channel #00h)                 
351 	11/24/2010-15:25:55  	Power Unit /Pwr Unit Redund (#0x02) 	Informational event: Pwr Unit Redund reports the unit has regained the minimum amount of resources needed for normal operation.                                                                                                                           	BMC - LUN #0 (Channel #00h)                 
352 	11/24/2010-15:25:55  	Power Supply /PS1 Status (#0x50)    	Informational event: PS1 Status reports the power supply has recovered from the failure.                                                                                                                                                                  	BMC - LUN #0 (Channel #00h)                 
353 	11/24/2010-15:25:55  	Power Supply /PS1 Status (#0x50)    	Informational event: PS1 Status reports the power supply's input (AC/DC) has been regained.                                                                                                                                                               	BMC - LUN #0 (Channel #00h)                 
354 	11/24/2010-15:25:56  	Power Unit /Pwr Unit Redund (#0x02) 	Informational event: Pwr Unit Redund reports full redundancy has been regained .                                                                                                                                                                          	BMC - LUN #0 (Channel #00h)                 
355 	11/24/2010-15:25:56  	Power Unit /Pwr Unit Redund (#0x02) 	Informational event: Pwr Unit Redund reports full redundancy has been regained.                                                                                                                                                                           	BMC - LUN #0 (Channel #00h)                 
356 	11/24/2010-15:25:56  	Power Unit /Pwr Unit Redund (#0x02) 	Informational event: Pwr Unit Redund reports the unit has regained the minimum amount of resources needed for normal operation.                                                                                                                           	BMC - LUN #0 (Channel #00h)                 
357 	11/24/2010-15:26:57  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports a system boot event has occurred.                                                                                                                                                                            	BIOS (Channel #00h)                         
358 	11/24/2010-15:27:25  	OS Boot #0x00                       	Informational event: System Management Software states that OS Boot sensor 0 reports the boot from drive C has been completed.                                                                                                                            	System Management Software (Channel #00h)   
359 	11/24/2010-15:27:25  	OEM Event                           	Operating system bootup                                                                                                                                                                                                                                   	 OEM Event                                  
360 	11/24/2010-15:37:25  	OS Stop / Shutdown #0x00            	Warning event: System Management Software states that OS Stop/Shutdown sensor 0 reports a OS graceful shutdown.                                                                                                                                           	System Management Software (Channel #00h)   
361 	11/24/2010-15:37:25  	OEM Event                           	Operating system shutdown                                                                                                                                                                                                                                 	 OEM Event                                  
362 	11/24/2010-15:37:34  	System Event #0x83                  	Informational event: System Event sensor 131 reports Timestamp Clock Sync. Event is first of two expected events from BIOS on every power on.                                                                                                             	BIOS (Channel #00h)                         
363 	11/24/2010-15:37:36  	System Event #0x83                  	Informational event: System Event sensor 131 reports Timestamp Clock Sync. Event is first of two expected events from BIOS on every power on.                                                                                                             	BIOS (Channel #00h)                         
364 	11/24/2010-15:37:37  	Power Unit /Pwr Unit Status (#0x01) 	Informational event: Pwr Unit Status reports the power unit is powered off or being powered down.                                                                                                                                                         	BMC - LUN #0 (Channel #00h)                 
365 	11/24/2010-15:39:16  	Power Supply /PS1 Status (#0x50)    	CRITICAL event: PS1 Status reports the power supply has suffered a failure.                                                                                                                                                                               	BMC - LUN #0 (Channel #00h)                 
366 	11/24/2010-15:39:16  	Power Supply /PS1 Status (#0x50)    	Warning event: PS1 Status reports the power supply's input (AC/DC) has been lost.                                                                                                                                                                         	BMC - LUN #0 (Channel #00h)                 
367 	12/13/2010-16:35:27  	Power Unit /Pwr Unit Status (#0x01) 	Informational event: Pwr Unit Status reports the power unit is powered off or being powered down.                                                                                                                                                         	BMC - LUN #0 (Channel #00h)                 
368 	12/13/2010-16:35:28  	Processor /P1 Status (#0x60)        	Informational event: P1 Status reports the processor's presence has been detected.                                                                                                                                                                        	BMC - LUN #0 (Channel #00h)                 
369 	12/13/2010-16:35:28  	Processor /P2 Status (#0x61)        	Informational event: P2 Status reports the processor's presence has been detected.                                                                                                                                                                        	BMC - LUN #0 (Channel #00h)                 
370 	12/13/2010-16:35:31  	Power Supply /PS1 Status (#0x50)    	Informational event: PS1 Status reports the power supply's presence has been detected.                                                                                                                                                                    	BMC - LUN #0 (Channel #00h)                 
371 	12/13/2010-16:35:31  	Power Supply /PS2 Status (#0x51)    	Informational event: PS2 Status reports the power supply's presence has been detected.                                                                                                                                                                    	BMC - LUN #0 (Channel #00h)                 
372 	12/13/2010-16:35:32  	Power Unit /Pwr Unit Redund (#0x02) 	Informational event: Pwr Unit Redund reports full redundancy has been regained .                                                                                                                                                                          	BMC - LUN #0 (Channel #00h)                 
373 	12/13/2010-16:35:48  	Power Unit /Pwr Unit Status (#0x01) 	Informational event: Pwr Unit Status reports the power unit is powered off or being powered down.                                                                                                                                                         	BMC - LUN #0 (Channel #00h)                 
374 	12/13/2010-16:35:48  	Button /Button (#0x09)              	Informational event: Button reports the power button has been pressed.                                                                                                                                                                                    	BMC - LUN #0 (Channel #00h)                 
375 	12/13/2010-16:35:51  	Power Unit /Pwr Unit Redund (#0x02) 	Informational event: Pwr Unit Redund reports full redundancy has been regained .                                                                                                                                                                          	BMC - LUN #0 (Channel #00h)                 
376 	12/13/2010-16:35:54  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is first of two expected events from BIOS on every power on.                                                                                                                     	BIOS (Channel #00h)                         
377 	12/13/2010-16:35:55  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is second of two expected events from BIOS on every power on.                                                                                                                    	BIOS (Channel #00h)                         
378 	12/13/2010-16:37:14  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports a system boot event has occurred.                                                                                                                                                                            	BIOS (Channel #00h)                         
379 	12/13/2010-16:37:42  	OS Boot #0x00                       	Informational event: System Management Software states that OS Boot sensor 0 reports the boot from drive C has been completed.                                                                                                                            	System Management Software (Channel #00h)   
380 	12/13/2010-16:37:42  	OEM Event                           	Operating system bootup                                                                                                                                                                                                                                   	 OEM Event                                  
381 	12/13/2010-16:44:37  	Physical Security (Chassis Intrusion	Warning event: Physical Scrty reports LAN Leash has been lost.                                                                                                                                                                                            	BMC - LUN #0 (Channel #00h)                 
382 	12/13/2010-16:45:58  	Physical Security (Chassis Intrusion	Informational event: Physical Scrty reports LAN Leash has been regained.                                                                                                                                                                                  	BMC - LUN #0 (Channel #00h)                 
383 	12/13/2010-16:48:37  	Power Supply /PS1 Status (#0x50)    	CRITICAL event: PS1 Status reports the power supply has suffered a failure.                                                                                                                                                                               	BMC - LUN #0 (Channel #00h)                 
384 	12/13/2010-16:48:37  	Power Supply /PS1 Status (#0x50)    	Warning event: PS1 Status reports the power supply's input (AC/DC) has been lost.                                                                                                                                                                         	BMC - LUN #0 (Channel #00h)                 
385 	12/13/2010-16:48:38  	Power Unit /Pwr Unit Redund (#0x02) 	Warning event: Pwr Unit Redund reports redundancy has been lost.                                                                                                                                                                                          	BMC - LUN #0 (Channel #00h)                 
386 	12/13/2010-16:48:38  	Power Unit /Pwr Unit Redund (#0x02) 	Warning event: Pwr Unit Redund reports redundancy has been lost .                                                                                                                                                                                         	BMC - LUN #0 (Channel #00h)                 
387 	12/13/2010-16:48:38  	Power Unit /Pwr Unit Redund (#0x02) 	Warning event: Pwr Unit Redund reports redundancy has been lost, but the unit is still functioning with the minimum amount of resources needed for normal operation.                                                                                      	BMC - LUN #0 (Channel #00h)                 
388 	12/13/2010-16:48:42  	Power Supply /PS1 Status (#0x50)    	Informational event: PS1 Status reports the power supply has recovered from the failure.                                                                                                                                                                  	BMC - LUN #0 (Channel #00h)                 
389 	12/13/2010-16:48:42  	Power Supply /PS1 Status (#0x50)    	Informational event: PS1 Status reports the power supply's input (AC/DC) has been regained.                                                                                                                                                               	BMC - LUN #0 (Channel #00h)                 
390 	12/13/2010-16:48:43  	Power Unit /Pwr Unit Redund (#0x02) 	Informational event: Pwr Unit Redund reports full redundancy has been regained .                                                                                                                                                                          	BMC - LUN #0 (Channel #00h)                 
391 	12/13/2010-16:48:43  	Power Unit /Pwr Unit Redund (#0x02) 	Informational event: Pwr Unit Redund reports full redundancy has been regained.                                                                                                                                                                           	BMC - LUN #0 (Channel #00h)                 
392 	12/13/2010-16:48:43  	Power Unit /Pwr Unit Redund (#0x02) 	Informational event: Pwr Unit Redund reports redundancy has been lost, but the unit is still functioning with the minimum amount of resources needed for normal operation.                                                                                	BMC - LUN #0 (Channel #00h)                 
393 	12/13/2010-16:59:05  	OS Stop / Shutdown #0x00            	Warning event: System Management Software states that OS Stop/Shutdown sensor 0 reports a OS graceful shutdown.                                                                                                                                           	System Management Software (Channel #00h)   
394 	12/13/2010-16:59:05  	OEM Event                           	Operating system shutdown                                                                                                                                                                                                                                 	 OEM Event                                  
395 	12/13/2010-16:59:11  	System Event #0x83                  	Informational event: System Event sensor 131 reports Timestamp Clock Sync. Event is first of two expected events from BIOS on every power on.                                                                                                             	BIOS (Channel #00h)                         
396 	12/13/2010-16:59:13  	System Event #0x83                  	Informational event: System Event sensor 131 reports Timestamp Clock Sync. Event is first of two expected events from BIOS on every power on.                                                                                                             	BIOS (Channel #00h)                         
397 	12/13/2010-16:59:14  	Power Unit /Pwr Unit Redund (#0x02) 	Informational event: Pwr Unit Redund reports full redundancy has been regained .                                                                                                                                                                          	BMC - LUN #0 (Channel #00h)                 
398 	12/13/2010-16:59:19  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is first of two expected events from BIOS on every power on.                                                                                                                     	BIOS (Channel #00h)                         
399 	12/13/2010-15:59:08  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is second of two expected events from BIOS on every power on.                                                                                                                    	BIOS (Channel #00h)                         
400 	12/13/2010-16:00:30  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports a system boot event has occurred.                                                                                                                                                                            	BIOS (Channel #00h)                         
401 	12/13/2010-16:02:35  	Power Unit /Pwr Unit Redund (#0x02) 	Informational event: Pwr Unit Redund reports full redundancy has been regained .                                                                                                                                                                          	BMC - LUN #0 (Channel #00h)                 
402 	12/13/2010-16:02:40  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is first of two expected events from BIOS on every power on.                                                                                                                     	BIOS (Channel #00h)                         
403 	12/13/2010-16:02:41  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is second of two expected events from BIOS on every power on.                                                                                                                    	BIOS (Channel #00h)                         
404 	12/13/2010-16:04:54  	Power Unit /Pwr Unit Redund (#0x02) 	Informational event: Pwr Unit Redund reports full redundancy has been regained .                                                                                                                                                                          	BMC - LUN #0 (Channel #00h)                 
405 	12/13/2010-16:04:58  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is first of two expected events from BIOS on every power on.                                                                                                                     	BIOS (Channel #00h)                         
406 	12/13/2010-16:04:59  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is second of two expected events from BIOS on every power on.                                                                                                                    	BIOS (Channel #00h)                         
407 	12/13/2010-16:06:06  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports a system boot event has occurred.                                                                                                                                                                            	BIOS (Channel #00h)                         
408 	12/13/2010-16:10:56  	OS Stop / Shutdown #0x00            	Warning event: System Management Software states that OS Stop/Shutdown sensor 0 reports a OS graceful shutdown.                                                                                                                                           	System Management Software (Channel #00h)   
409 	12/13/2010-16:10:56  	OEM Event                           	Operating system shutdown                                                                                                                                                                                                                                 	 OEM Event                                  
410 	12/13/2010-16:10:58  	System Event #0x83                  	Informational event: System Event sensor 131 reports Timestamp Clock Sync. Event is first of two expected events from BIOS on every power on.                                                                                                             	BIOS (Channel #00h)                         
411 	12/13/2010-16:10:59  	System Event #0x83                  	Informational event: System Event sensor 131 reports Timestamp Clock Sync. Event is first of two expected events from BIOS on every power on.                                                                                                             	BIOS (Channel #00h)                         
412 	12/13/2010-16:11:00  	Power Unit /Pwr Unit Redund (#0x02) 	Informational event: Pwr Unit Redund reports full redundancy has been regained .                                                                                                                                                                          	BMC - LUN #0 (Channel #00h)                 
413 	12/13/2010-16:11:05  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is first of two expected events from BIOS on every power on.                                                                                                                     	BIOS (Channel #00h)                         
414 	12/13/2010-16:11:06  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is second of two expected events from BIOS on every power on.                                                                                                                    	BIOS (Channel #00h)                         
415 	12/13/2010-16:12:35  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports a system boot event has occurred.                                                                                                                                                                            	BIOS (Channel #00h)                         
416 	12/13/2010-16:17:10  	OS Stop / Shutdown #0x00            	Warning event: System Management Software states that OS Stop/Shutdown sensor 0 reports a OS graceful shutdown.                                                                                                                                           	System Management Software (Channel #00h)   
417 	12/13/2010-16:17:10  	OEM Event                           	Operating system shutdown                                                                                                                                                                                                                                 	 OEM Event                                  
418 	12/13/2010-16:17:11  	System Event #0x83                  	Informational event: System Event sensor 131 reports Timestamp Clock Sync. Event is first of two expected events from BIOS on every power on.                                                                                                             	BIOS (Channel #00h)                         
419 	12/13/2010-16:17:13  	System Event #0x83                  	Informational event: System Event sensor 131 reports Timestamp Clock Sync. Event is first of two expected events from BIOS on every power on.                                                                                                             	BIOS (Channel #00h)                         
420 	12/13/2010-16:17:14  	Power Unit /Pwr Unit Redund (#0x02) 	Informational event: Pwr Unit Redund reports full redundancy has been regained .                                                                                                                                                                          	BMC - LUN #0 (Channel #00h)                 
421 	12/13/2010-16:17:19  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is first of two expected events from BIOS on every power on.                                                                                                                     	BIOS (Channel #00h)                         
422 	12/13/2010-16:17:19  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is second of two expected events from BIOS on every power on.                                                                                                                    	BIOS (Channel #00h)                         
423 	12/13/2010-16:18:23  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports a system boot event has occurred.                                                                                                                                                                            	BIOS (Channel #00h)                         
424 	12/14/2010-03:31:04  	OS Stop / Shutdown #0x00            	Warning event: System Management Software states that OS Stop/Shutdown sensor 0 reports a OS graceful shutdown.                                                                                                                                           	System Management Software (Channel #00h)   
425 	12/14/2010-03:31:04  	OEM Event                           	Operating system shutdown                                                                                                                                                                                                                                 	 OEM Event                                  
426 	12/14/2010-03:31:06  	System Event #0x83                  	Informational event: System Event sensor 131 reports Timestamp Clock Sync. Event is first of two expected events from BIOS on every power on.                                                                                                             	BIOS (Channel #00h)                         
427 	12/14/2010-03:31:07  	System Event #0x83                  	Informational event: System Event sensor 131 reports Timestamp Clock Sync. Event is first of two expected events from BIOS on every power on.                                                                                                             	BIOS (Channel #00h)                         
428 	12/14/2010-03:31:08  	Power Unit /Pwr Unit Redund (#0x02) 	Informational event: Pwr Unit Redund reports full redundancy has been regained .                                                                                                                                                                          	BMC - LUN #0 (Channel #00h)                 
429 	12/14/2010-03:31:13  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is first of two expected events from BIOS on every power on.                                                                                                                     	BIOS (Channel #00h)                         
430 	12/14/2010-03:29:48  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is second of two expected events from BIOS on every power on.                                                                                                                    	BIOS (Channel #00h)                         
431 	12/14/2010-07:58:04  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports a system boot event has occurred.                                                                                                                                                                            	BIOS (Channel #00h)                         
432 	12/14/2010-07:58:29  	OS Boot #0x00                       	Informational event: System Management Software states that OS Boot sensor 0 reports the boot from drive C has been completed.                                                                                                                            	System Management Software (Channel #00h)   
433 	12/14/2010-07:58:29  	OEM Event                           	Operating system bootup                                                                                                                                                                                                                                   	 OEM Event                                  
434 	12/14/2010-07:59:40  	OS Stop / Shutdown #0x00            	Warning event: System Management Software states that OS Stop/Shutdown sensor 0 reports a OS graceful shutdown.                                                                                                                                           	System Management Software (Channel #00h)   
435 	12/14/2010-07:59:40  	OEM Event                           	Operating system shutdown                                                                                                                                                                                                                                 	 OEM Event                                  
436 	12/14/2010-07:59:41  	System Event #0x83                  	Informational event: System Event sensor 131 reports Timestamp Clock Sync. Event is first of two expected events from BIOS on every power on.                                                                                                             	BIOS (Channel #00h)                         
437 	12/14/2010-07:59:43  	System Event #0x83                  	Informational event: System Event sensor 131 reports Timestamp Clock Sync. Event is first of two expected events from BIOS on every power on.                                                                                                             	BIOS (Channel #00h)                         
438 	12/14/2010-07:59:44  	Power Unit /Pwr Unit Status (#0x01) 	Informational event: Pwr Unit Status reports the power unit is powered off or being powered down.                                                                                                                                                         	BMC - LUN #0 (Channel #00h)                 
439 	12/14/2010-07:59:52  	Power Supply /PS2 Status (#0x51)    	CRITICAL event: PS2 Status reports the power supply has suffered a failure.                                                                                                                                                                               	BMC - LUN #0 (Channel #00h)                 
440 	12/14/2010-07:59:52  	Power Supply /PS2 Status (#0x51)    	Warning event: PS2 Status reports the power supply's input (AC/DC) has been lost.                                                                                                                                                                         	BMC - LUN #0 (Channel #00h)                 
441 	12/14/2010-07:59:53  	Power Unit /Pwr Unit Redund (#0x02) 	Warning event: Pwr Unit Redund reports redundancy has been lost.                                                                                                                                                                                          	BMC - LUN #0 (Channel #00h)                 
442 	12/14/2010-07:59:53  	Power Unit /Pwr Unit Redund (#0x02) 	Warning event: Pwr Unit Redund reports redundancy has been lost .                                                                                                                                                                                         	BMC - LUN #0 (Channel #00h)                 
443 	12/14/2010-07:59:53  	Power Unit /Pwr Unit Redund (#0x02) 	Warning event: Pwr Unit Redund reports redundancy has been lost, but the unit is still functioning with the minimum amount of resources needed for normal operation.                                                                                      	BMC - LUN #0 (Channel #00h)                 
444 	01/11/2011-16:16:31  	Power Unit /Pwr Unit Status (#0x01) 	Informational event: Pwr Unit Status reports the power unit is powered off or being powered down.                                                                                                                                                         	BMC - LUN #0 (Channel #00h)                 
445 	01/11/2011-16:16:32  	Processor /P1 Status (#0x60)        	Informational event: P1 Status reports the processor's presence has been detected.                                                                                                                                                                        	BMC - LUN #0 (Channel #00h)                 
446 	01/11/2011-16:16:32  	Processor /P2 Status (#0x61)        	Informational event: P2 Status reports the processor's presence has been detected.                                                                                                                                                                        	BMC - LUN #0 (Channel #00h)                 
447 	01/11/2011-16:16:36  	Power Supply /PS1 Status (#0x50)    	Informational event: PS1 Status reports the power supply's presence has been detected.                                                                                                                                                                    	BMC - LUN #0 (Channel #00h)                 
448 	01/11/2011-16:16:36  	Power Supply /PS1 Status (#0x50)    	CRITICAL event: PS1 Status reports the power supply has suffered a failure.                                                                                                                                                                               	BMC - LUN #0 (Channel #00h)                 
449 	01/11/2011-16:16:36  	Power Supply /PS1 Status (#0x50)    	Warning event: PS1 Status reports the power supply's input (AC/DC) has been lost.                                                                                                                                                                         	BMC - LUN #0 (Channel #00h)                 
450 	01/11/2011-16:16:36  	Power Supply /PS2 Status (#0x51)    	Informational event: PS2 Status reports the power supply's presence has been detected.                                                                                                                                                                    	BMC - LUN #0 (Channel #00h)                 
451 	01/11/2011-16:16:37  	Power Unit /Pwr Unit Redund (#0x02) 	Warning event: Pwr Unit Redund reports redundancy has been lost .                                                                                                                                                                                         	BMC - LUN #0 (Channel #00h)                 
452 	01/11/2011-16:16:37  	Power Unit /Pwr Unit Redund (#0x02) 	Informational event: Pwr Unit Redund reports the unit has regained the minimum amount of resources needed for normal operation.                                                                                                                           	BMC - LUN #0 (Channel #00h)                 
453 	01/11/2011-16:16:37  	Power Supply /PS1 Status (#0x50)    	Informational event: PS1 Status reports the power supply has recovered from the failure.                                                                                                                                                                  	BMC - LUN #0 (Channel #00h)                 
454 	01/11/2011-16:16:37  	Power Supply /PS1 Status (#0x50)    	Informational event: PS1 Status reports the power supply's input (AC/DC) has been regained.                                                                                                                                                               	BMC - LUN #0 (Channel #00h)                 
455 	01/11/2011-16:16:38  	Power Unit /Pwr Unit Redund (#0x02) 	Informational event: Pwr Unit Redund reports full redundancy has been regained .                                                                                                                                                                          	BMC - LUN #0 (Channel #00h)                 
456 	01/11/2011-16:16:38  	Power Unit /Pwr Unit Redund (#0x02) 	Informational event: Pwr Unit Redund reports full redundancy has been regained.                                                                                                                                                                           	BMC - LUN #0 (Channel #00h)                 
457 	01/11/2011-16:16:38  	Power Unit /Pwr Unit Redund (#0x02) 	Informational event: Pwr Unit Redund reports the unit has regained the minimum amount of resources needed for normal operation.                                                                                                                           	BMC - LUN #0 (Channel #00h)                 
458 	01/11/2011-16:17:44  	Power Unit /Pwr Unit Status (#0x01) 	Informational event: Pwr Unit Status reports the power unit is powered off or being powered down.                                                                                                                                                         	BMC - LUN #0 (Channel #00h)                 
459 	01/11/2011-16:17:44  	Button /Button (#0x09)              	Informational event: Button reports the power button has been pressed.                                                                                                                                                                                    	BMC - LUN #0 (Channel #00h)                 
460 	01/11/2011-16:17:47  	Power Unit /Pwr Unit Redund (#0x02) 	Informational event: Pwr Unit Redund reports full redundancy has been regained .                                                                                                                                                                          	BMC - LUN #0 (Channel #00h)                 
461 	01/11/2011-16:17:50  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is first of two expected events from BIOS on every power on.                                                                                                                     	BIOS (Channel #00h)                         
462 	01/11/2011-16:17:51  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is second of two expected events from BIOS on every power on.                                                                                                                    	BIOS (Channel #00h)                         
463 	01/11/2011-16:24:48  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports a system boot event has occurred.                                                                                                                                                                            	BIOS (Channel #00h)                         
464 	01/11/2011-16:25:14  	OS Boot #0x00                       	Informational event: System Management Software states that OS Boot sensor 0 reports the boot from drive C has been completed.                                                                                                                            	System Management Software (Channel #00h)   
465 	01/11/2011-16:25:14  	OEM Event                           	Operating system bootup                                                                                                                                                                                                                                   	 OEM Event                                  
466 	01/11/2011-16:51:27  	OS Stop / Shutdown #0x00            	Warning event: System Management Software states that OS Stop/Shutdown sensor 0 reports a OS graceful shutdown.                                                                                                                                           	System Management Software (Channel #00h)   
467 	01/11/2011-16:51:27  	OEM Event                           	Operating system shutdown                                                                                                                                                                                                                                 	 OEM Event                                  
468 	01/11/2011-16:51:28  	System Event #0x83                  	Informational event: System Event sensor 131 reports Timestamp Clock Sync. Event is first of two expected events from BIOS on every power on.                                                                                                             	BIOS (Channel #00h)                         
469 	01/11/2011-16:51:30  	System Event #0x83                  	Informational event: System Event sensor 131 reports Timestamp Clock Sync. Event is first of two expected events from BIOS on every power on.                                                                                                             	BIOS (Channel #00h)                         
470 	01/11/2011-16:51:31  	Power Unit /Pwr Unit Redund (#0x02) 	Informational event: Pwr Unit Redund reports full redundancy has been regained .                                                                                                                                                                          	BMC - LUN #0 (Channel #00h)                 
471 	01/11/2011-16:51:36  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is first of two expected events from BIOS on every power on.                                                                                                                     	BIOS (Channel #00h)                         
472 	01/11/2011-16:51:21  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is second of two expected events from BIOS on every power on.                                                                                                                    	BIOS (Channel #00h)                         
473 	01/11/2011-16:52:44  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports a system boot event has occurred.                                                                                                                                                                            	BIOS (Channel #00h)                         
474 	01/11/2011-16:53:06  	OS Boot #0x00                       	Informational event: System Management Software states that OS Boot sensor 0 reports the boot from drive C has been completed.                                                                                                                            	System Management Software (Channel #00h)   
475 	01/11/2011-16:53:06  	OEM Event                           	Operating system bootup                                                                                                                                                                                                                                   	 OEM Event                                  
476 	01/12/2011-08:35:19  	OS Stop / Shutdown #0x00            	Warning event: System Management Software states that OS Stop/Shutdown sensor 0 reports a OS graceful shutdown.                                                                                                                                           	System Management Software (Channel #00h)   
477 	01/12/2011-08:35:19  	OEM Event                           	Operating system shutdown                                                                                                                                                                                                                                 	 OEM Event                                  
478 	01/12/2011-08:35:21  	System Event #0x83                  	Informational event: System Event sensor 131 reports Timestamp Clock Sync. Event is first of two expected events from BIOS on every power on.                                                                                                             	BIOS (Channel #00h)                         
479 	01/12/2011-08:35:23  	System Event #0x83                  	Informational event: System Event sensor 131 reports Timestamp Clock Sync. Event is first of two expected events from BIOS on every power on.                                                                                                             	BIOS (Channel #00h)                         
480 	01/12/2011-08:35:23  	Power Unit /Pwr Unit Redund (#0x02) 	Informational event: Pwr Unit Redund reports full redundancy has been regained .                                                                                                                                                                          	BMC - LUN #0 (Channel #00h)                 
481 	01/12/2011-08:35:28  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is first of two expected events from BIOS on every power on.                                                                                                                     	BIOS (Channel #00h)                         
482 	01/12/2011-08:35:26  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is second of two expected events from BIOS on every power on.                                                                                                                    	BIOS (Channel #00h)                         
483 	01/12/2011-08:37:43  	Power Unit /Pwr Unit Redund (#0x02) 	Informational event: Pwr Unit Redund reports full redundancy has been regained .                                                                                                                                                                          	BMC - LUN #0 (Channel #00h)                 
484 	01/12/2011-08:37:47  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is first of two expected events from BIOS on every power on.                                                                                                                     	BIOS (Channel #00h)                         
485 	01/12/2011-08:37:48  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is second of two expected events from BIOS on every power on.                                                                                                                    	BIOS (Channel #00h)                         
486 	01/12/2011-08:39:13  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports a system boot event has occurred.                                                                                                                                                                            	BIOS (Channel #00h)                         
487 	01/12/2011-08:39:35  	OS Boot #0x00                       	Informational event: System Management Software states that OS Boot sensor 0 reports the boot from drive C has been completed.                                                                                                                            	System Management Software (Channel #00h)   
488 	01/12/2011-08:39:35  	OEM Event                           	Operating system bootup                                                                                                                                                                                                                                   	 OEM Event                                  
489 	01/12/2011-08:40:53  	OS Stop / Shutdown #0x00            	Warning event: System Management Software states that OS Stop/Shutdown sensor 0 reports a OS graceful shutdown.                                                                                                                                           	System Management Software (Channel #00h)   
490 	01/12/2011-08:40:53  	OEM Event                           	Operating system shutdown                                                                                                                                                                                                                                 	 OEM Event                                  
491 	01/12/2011-08:40:55  	System Event #0x83                  	Informational event: System Event sensor 131 reports Timestamp Clock Sync. Event is first of two expected events from BIOS on every power on.                                                                                                             	BIOS (Channel #00h)                         
492 	01/12/2011-08:40:57  	System Event #0x83                  	Informational event: System Event sensor 131 reports Timestamp Clock Sync. Event is first of two expected events from BIOS on every power on.                                                                                                             	BIOS (Channel #00h)                         
493 	01/12/2011-08:40:57  	Power Unit /Pwr Unit Redund (#0x02) 	Informational event: Pwr Unit Redund reports full redundancy has been regained .                                                                                                                                                                          	BMC - LUN #0 (Channel #00h)                 
494 	01/12/2011-08:41:02  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is first of two expected events from BIOS on every power on.                                                                                                                     	BIOS (Channel #00h)                         
495 	01/12/2011-08:41:03  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is second of two expected events from BIOS on every power on.                                                                                                                    	BIOS (Channel #00h)                         
496 	01/12/2011-08:43:28  	Power Unit /Pwr Unit Redund (#0x02) 	Informational event: Pwr Unit Redund reports full redundancy has been regained .                                                                                                                                                                          	BMC - LUN #0 (Channel #00h)                 
497 	01/12/2011-08:43:33  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is first of two expected events from BIOS on every power on.                                                                                                                     	BIOS (Channel #00h)                         
498 	01/12/2011-08:43:34  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is second of two expected events from BIOS on every power on.                                                                                                                    	BIOS (Channel #00h)                         
499 	01/12/2011-08:45:02  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports a system boot event has occurred.                                                                                                                                                                            	BIOS (Channel #00h)                         
500 	01/12/2011-08:45:24  	OS Boot #0x00                       	Informational event: System Management Software states that OS Boot sensor 0 reports the boot from drive C has been completed.                                                                                                                            	System Management Software (Channel #00h)   
501 	01/12/2011-08:45:24  	OEM Event                           	Operating system bootup                                                                                                                                                                                                                                   	 OEM Event                                  
502 	01/12/2011-08:46:12  	OS Stop / Shutdown #0x00            	Warning event: System Management Software states that OS Stop/Shutdown sensor 0 reports a OS graceful shutdown.                                                                                                                                           	System Management Software (Channel #00h)   
503 	01/12/2011-08:46:12  	OEM Event                           	Operating system shutdown                                                                                                                                                                                                                                 	 OEM Event                                  
504 	01/12/2011-08:46:12  	System Event #0x83                  	Informational event: System Event sensor 131 reports Timestamp Clock Sync. Event is first of two expected events from BIOS on every power on.                                                                                                             	BIOS (Channel #00h)                         
505 	01/12/2011-08:46:14  	System Event #0x83                  	Informational event: System Event sensor 131 reports Timestamp Clock Sync. Event is first of two expected events from BIOS on every power on.                                                                                                             	BIOS (Channel #00h)                         
506 	01/12/2011-08:46:15  	Power Unit /Pwr Unit Status (#0x01) 	Informational event: Pwr Unit Status reports the power unit is powered off or being powered down.                                                                                                                                                         	BMC - LUN #0 (Channel #00h)                 
507 	01/12/2011-11:21:02  	Power Unit /Pwr Unit Status (#0x01) 	Informational event: Pwr Unit Status reports the power unit is powered off or being powered down.                                                                                                                                                         	BMC - LUN #0 (Channel #00h)                 
508 	01/12/2011-11:21:02  	Button /Button (#0x09)              	Informational event: Button reports the power button has been pressed.                                                                                                                                                                                    	BMC - LUN #0 (Channel #00h)                 
509 	01/12/2011-11:21:05  	Power Unit /Pwr Unit Redund (#0x02) 	Informational event: Pwr Unit Redund reports full redundancy has been regained .                                                                                                                                                                          	BMC - LUN #0 (Channel #00h)                 
510 	01/12/2011-11:21:08  	Physical Security (Chassis Intrusion	Warning event: Physical Scrty reports LAN Leash has been lost.                                                                                                                                                                                            	BMC - LUN #0 (Channel #00h)                 
511 	01/12/2011-11:21:08  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is first of two expected events from BIOS on every power on.                                                                                                                     	BIOS (Channel #00h)                         
512 	01/12/2011-11:21:07  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is second of two expected events from BIOS on every power on.                                                                                                                    	BIOS (Channel #00h)                         
513 	01/12/2011-11:27:06  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports a system boot event has occurred.                                                                                                                                                                            	BIOS (Channel #00h)                         
514 	01/12/2011-11:27:31  	OS Boot #0x00                       	Informational event: System Management Software states that OS Boot sensor 0 reports the boot from drive C has been completed.                                                                                                                            	System Management Software (Channel #00h)   
515 	01/12/2011-11:27:31  	OEM Event                           	Operating system bootup                                                                                                                                                                                                                                   	 OEM Event                                  
516 	01/12/2011-11:36:46  	OS Stop / Shutdown #0x00            	Warning event: System Management Software states that OS Stop/Shutdown sensor 0 reports a OS graceful shutdown.                                                                                                                                           	System Management Software (Channel #00h)   
517 	01/12/2011-11:36:46  	OEM Event                           	Operating system shutdown                                                                                                                                                                                                                                 	 OEM Event                                  
518 	01/12/2011-11:36:54  	System Event #0x83                  	Informational event: System Event sensor 131 reports Timestamp Clock Sync. Event is first of two expected events from BIOS on every power on.                                                                                                             	BIOS (Channel #00h)                         
519 	01/12/2011-11:36:56  	System Event #0x83                  	Informational event: System Event sensor 131 reports Timestamp Clock Sync. Event is first of two expected events from BIOS on every power on.                                                                                                             	BIOS (Channel #00h)                         
520 	01/12/2011-11:36:58  	Power Unit /Pwr Unit Status (#0x01) 	Informational event: Pwr Unit Status reports the power unit is powered off or being powered down.                                                                                                                                                         	BMC - LUN #0 (Channel #00h)                 
521 	01/12/2011-13:01:40  	Power Unit /Pwr Unit Status (#0x01) 	Informational event: Pwr Unit Status reports the power unit is powered off or being powered down.                                                                                                                                                         	BMC - LUN #0 (Channel #00h)                 
522 	01/12/2011-13:01:40  	Button /Button (#0x09)              	Informational event: Button reports the power button has been pressed.                                                                                                                                                                                    	BMC - LUN #0 (Channel #00h)                 
523 	01/12/2011-13:01:43  	Physical Security (Chassis Intrusion	Informational event: Physical Scrty reports LAN Leash has been regained.                                                                                                                                                                                  	BMC - LUN #0 (Channel #00h)                 
524 	01/12/2011-13:01:43  	Physical Security (Chassis Intrusion	Warning event: Physical Scrty reports LAN Leash has been lost.                                                                                                                                                                                            	BMC - LUN #0 (Channel #00h)                 
525 	01/12/2011-13:01:43  	Power Unit /Pwr Unit Redund (#0x02) 	Informational event: Pwr Unit Redund reports full redundancy has been regained .                                                                                                                                                                          	BMC - LUN #0 (Channel #00h)                 
526 	01/12/2011-13:01:46  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is first of two expected events from BIOS on every power on.                                                                                                                     	BIOS (Channel #00h)                         
527 	01/12/2011-13:01:47  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is second of two expected events from BIOS on every power on.                                                                                                                    	BIOS (Channel #00h)                         
528 	01/12/2011-13:03:10  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports a system boot event has occurred.                                                                                                                                                                            	BIOS (Channel #00h)                         
529 	01/12/2011-13:03:35  	OS Boot #0x00                       	Informational event: System Management Software states that OS Boot sensor 0 reports the boot from drive C has been completed.                                                                                                                            	System Management Software (Channel #00h)   
530 	01/12/2011-13:03:35  	OEM Event                           	Operating system bootup                                                                                                                                                                                                                                   	 OEM Event                                  
531 	01/12/2011-13:31:47  	OS Stop / Shutdown #0x00            	Warning event: System Management Software states that OS Stop/Shutdown sensor 0 reports a OS graceful shutdown.                                                                                                                                           	System Management Software (Channel #00h)   
532 	01/12/2011-13:31:47  	OEM Event                           	Operating system shutdown                                                                                                                                                                                                                                 	 OEM Event                                  
533 	01/12/2011-13:31:58  	System Event #0x83                  	Informational event: System Event sensor 131 reports Timestamp Clock Sync. Event is first of two expected events from BIOS on every power on.                                                                                                             	BIOS (Channel #00h)                         
534 	01/12/2011-13:32:00  	System Event #0x83                  	Informational event: System Event sensor 131 reports Timestamp Clock Sync. Event is first of two expected events from BIOS on every power on.                                                                                                             	BIOS (Channel #00h)                         
535 	01/12/2011-13:32:01  	Power Unit /Pwr Unit Status (#0x01) 	Informational event: Pwr Unit Status reports the power unit is powered off or being powered down.                                                                                                                                                         	BMC - LUN #0 (Channel #00h)                 
536 	01/12/2011-14:24:32  	Power Unit /Pwr Unit Status (#0x01) 	Informational event: Pwr Unit Status reports the power unit is powered off or being powered down.                                                                                                                                                         	BMC - LUN #0 (Channel #00h)                 
537 	01/12/2011-14:24:32  	Button /Button (#0x09)              	Informational event: Button reports the power button has been pressed.                                                                                                                                                                                    	BMC - LUN #0 (Channel #00h)                 
538 	01/12/2011-14:24:35  	Physical Security (Chassis Intrusion	Informational event: Physical Scrty reports LAN Leash has been regained.                                                                                                                                                                                  	BMC - LUN #0 (Channel #00h)                 
539 	01/12/2011-14:24:35  	Physical Security (Chassis Intrusion	Warning event: Physical Scrty reports LAN Leash has been lost.                                                                                                                                                                                            	BMC - LUN #0 (Channel #00h)                 
540 	01/12/2011-14:24:35  	Power Unit /Pwr Unit Redund (#0x02) 	Informational event: Pwr Unit Redund reports full redundancy has been regained .                                                                                                                                                                          	BMC - LUN #0 (Channel #00h)                 
541 	01/12/2011-14:24:39  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is first of two expected events from BIOS on every power on.                                                                                                                     	BIOS (Channel #00h)                         
542 	01/12/2011-14:24:39  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is second of two expected events from BIOS on every power on.                                                                                                                    	BIOS (Channel #00h)                         
543 	01/12/2011-14:24:39  	Physical Security (Chassis Intrusion	Informational event: Physical Scrty reports LAN Leash has been regained.                                                                                                                                                                                  	BMC - LUN #0 (Channel #00h)                 
544 	01/12/2011-14:29:50  	Power Unit /Pwr Unit Status (#0x01) 	Informational event: Pwr Unit Status reports the power unit is powered off or being powered down.                                                                                                                                                         	BMC - LUN #0 (Channel #00h)                 
545 	01/12/2011-14:29:50  	Button /Button (#0x09)              	Informational event: Button reports the power button has been pressed.                                                                                                                                                                                    	BMC - LUN #0 (Channel #00h)                 
546 	01/13/2011-06:46:43  	Power Unit /Pwr Unit Status (#0x01) 	Informational event: Pwr Unit Status reports the power unit is powered off or being powered down.                                                                                                                                                         	BMC - LUN #0 (Channel #00h)                 
547 	01/13/2011-06:46:44  	Processor /P1 Status (#0x60)        	Informational event: P1 Status reports the processor's presence has been detected.                                                                                                                                                                        	BMC - LUN #0 (Channel #00h)                 
548 	01/13/2011-06:46:44  	Processor /P2 Status (#0x61)        	Informational event: P2 Status reports the processor's presence has been detected.                                                                                                                                                                        	BMC - LUN #0 (Channel #00h)                 
549 	01/13/2011-06:46:48  	Power Supply /PS1 Status (#0x50)    	Informational event: PS1 Status reports the power supply's presence has been detected.                                                                                                                                                                    	BMC - LUN #0 (Channel #00h)                 
550 	01/13/2011-06:46:48  	Power Supply /PS2 Status (#0x51)    	Informational event: PS2 Status reports the power supply's presence has been detected.                                                                                                                                                                    	BMC - LUN #0 (Channel #00h)                 
551 	01/13/2011-06:46:49  	Power Unit /Pwr Unit Redund (#0x02) 	Informational event: Pwr Unit Redund reports full redundancy has been regained .                                                                                                                                                                          	BMC - LUN #0 (Channel #00h)                 
552 	01/13/2011-07:52:07  	Power Unit /Pwr Unit Status (#0x01) 	Informational event: Pwr Unit Status reports the power unit is powered off or being powered down.                                                                                                                                                         	BMC - LUN #0 (Channel #00h)                 
553 	01/13/2011-07:52:08  	Processor /P1 Status (#0x60)        	Informational event: P1 Status reports the processor's presence has been detected.                                                                                                                                                                        	BMC - LUN #0 (Channel #00h)                 
554 	01/13/2011-07:52:08  	Processor /P2 Status (#0x61)        	Informational event: P2 Status reports the processor's presence has been detected.                                                                                                                                                                        	BMC - LUN #0 (Channel #00h)                 
555 	01/13/2011-07:52:11  	Power Supply /PS1 Status (#0x50)    	Informational event: PS1 Status reports the power supply's presence has been detected.                                                                                                                                                                    	BMC - LUN #0 (Channel #00h)                 
556 	01/13/2011-07:52:11  	Power Supply /PS2 Status (#0x51)    	Informational event: PS2 Status reports the power supply's presence has been detected.                                                                                                                                                                    	BMC - LUN #0 (Channel #00h)                 
557 	01/13/2011-07:52:12  	Power Unit /Pwr Unit Redund (#0x02) 	Informational event: Pwr Unit Redund reports full redundancy has been regained .                                                                                                                                                                          	BMC - LUN #0 (Channel #00h)                 
558 	01/18/2011-08:06:56  	Power Supply /PS2 Status (#0x51)    	CRITICAL event: PS2 Status reports the power supply has suffered a failure.                                                                                                                                                                               	BMC - LUN #0 (Channel #00h)                 
559 	01/18/2011-08:06:56  	Power Supply /PS2 Status (#0x51)    	Warning event: PS2 Status reports the power supply's input (AC/DC) has been lost.                                                                                                                                                                         	BMC - LUN #0 (Channel #00h)                 
560 	01/18/2011-08:06:57  	Power Unit /Pwr Unit Redund (#0x02) 	Warning event: Pwr Unit Redund reports redundancy has been lost.                                                                                                                                                                                          	BMC - LUN #0 (Channel #00h)                 
561 	01/18/2011-08:06:57  	Power Unit /Pwr Unit Redund (#0x02) 	Warning event: Pwr Unit Redund reports redundancy has been lost .                                                                                                                                                                                         	BMC - LUN #0 (Channel #00h)                 
562 	01/18/2011-08:06:57  	Power Unit /Pwr Unit Redund (#0x02) 	Warning event: Pwr Unit Redund reports redundancy has been lost, but the unit is still functioning with the minimum amount of resources needed for normal operation.                                                                                      	BMC - LUN #0 (Channel #00h)                 
563 	01/19/2011-07:56:15  	Power Unit /Pwr Unit Status (#0x01) 	Informational event: Pwr Unit Status reports the power unit is powered off or being powered down.                                                                                                                                                         	BMC - LUN #0 (Channel #00h)                 
564 	01/19/2011-07:56:16  	Processor /P1 Status (#0x60)        	Informational event: P1 Status reports the processor's presence has been detected.                                                                                                                                                                        	BMC - LUN #0 (Channel #00h)                 
565 	01/19/2011-07:56:16  	Processor /P2 Status (#0x61)        	Informational event: P2 Status reports the processor's presence has been detected.                                                                                                                                                                        	BMC - LUN #0 (Channel #00h)                 
566 	01/19/2011-07:56:20  	Power Supply /PS1 Status (#0x50)    	Informational event: PS1 Status reports the power supply's presence has been detected.                                                                                                                                                                    	BMC - LUN #0 (Channel #00h)                 
567 	01/19/2011-07:56:20  	Power Supply /PS1 Status (#0x50)    	CRITICAL event: PS1 Status reports the power supply has suffered a failure.                                                                                                                                                                               	BMC - LUN #0 (Channel #00h)                 
568 	01/19/2011-07:56:20  	Power Supply /PS1 Status (#0x50)    	Warning event: PS1 Status reports the power supply's input (AC/DC) has been lost.                                                                                                                                                                         	BMC - LUN #0 (Channel #00h)                 
569 	01/19/2011-07:56:20  	Power Supply /PS2 Status (#0x51)    	Informational event: PS2 Status reports the power supply's presence has been detected.                                                                                                                                                                    	BMC - LUN #0 (Channel #00h)                 
570 	01/19/2011-07:56:21  	Power Unit /Pwr Unit Redund (#0x02) 	Warning event: Pwr Unit Redund reports redundancy has been lost .                                                                                                                                                                                         	BMC - LUN #0 (Channel #00h)                 
571 	01/19/2011-07:56:21  	Power Unit /Pwr Unit Redund (#0x02) 	Informational event: Pwr Unit Redund reports the unit has regained the minimum amount of resources needed for normal operation.                                                                                                                           	BMC - LUN #0 (Channel #00h)                 
572 	01/19/2011-07:56:21  	Power Supply /PS1 Status (#0x50)    	Informational event: PS1 Status reports the power supply has recovered from the failure.                                                                                                                                                                  	BMC - LUN #0 (Channel #00h)                 
573 	01/19/2011-07:56:21  	Power Supply /PS1 Status (#0x50)    	Informational event: PS1 Status reports the power supply's input (AC/DC) has been regained.                                                                                                                                                               	BMC - LUN #0 (Channel #00h)                 
574 	01/19/2011-07:56:22  	Power Unit /Pwr Unit Redund (#0x02) 	Informational event: Pwr Unit Redund reports full redundancy has been regained .                                                                                                                                                                          	BMC - LUN #0 (Channel #00h)                 
575 	01/19/2011-07:56:22  	Power Unit /Pwr Unit Redund (#0x02) 	Informational event: Pwr Unit Redund reports full redundancy has been regained.                                                                                                                                                                           	BMC - LUN #0 (Channel #00h)                 
576 	01/19/2011-07:56:22  	Power Unit /Pwr Unit Redund (#0x02) 	Informational event: Pwr Unit Redund reports the unit has regained the minimum amount of resources needed for normal operation.                                                                                                                           	BMC - LUN #0 (Channel #00h)                 
577 	01/19/2011-08:23:52  	Power Unit /Pwr Unit Status (#0x01) 	Informational event: Pwr Unit Status reports the power unit is powered off or being powered down.                                                                                                                                                         	BMC - LUN #0 (Channel #00h)                 
578 	01/19/2011-08:23:52  	Button /Button (#0x09)              	Informational event: Button reports the power button has been pressed.                                                                                                                                                                                    	BMC - LUN #0 (Channel #00h)                 
579 	01/19/2011-08:23:56  	Power Unit /Pwr Unit Redund (#0x02) 	Informational event: Pwr Unit Redund reports full redundancy has been regained .                                                                                                                                                                          	BMC - LUN #0 (Channel #00h)                 
580 	01/19/2011-08:23:59  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is first of two expected events from BIOS on every power on.                                                                                                                     	BIOS (Channel #00h)                         
581 	01/19/2011-08:24:00  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is second of two expected events from BIOS on every power on.                                                                                                                    	BIOS (Channel #00h)                         
582 	01/19/2011-08:25:43  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports a system boot event has occurred.                                                                                                                                                                            	BIOS (Channel #00h)                         
583 	01/19/2011-08:26:05  	OS Boot #0x00                       	Informational event: System Management Software states that OS Boot sensor 0 reports the boot from drive C has been completed.                                                                                                                            	System Management Software (Channel #00h)   
584 	01/19/2011-08:26:05  	OEM Event                           	Operating system bootup                                                                                                                                                                                                                                   	 OEM Event                                  
585 	01/19/2011-09:55:36  	Physical Security (Chassis Intrusion	Warning event: Physical Scrty reports LAN Leash has been lost.                                                                                                                                                                                            	BMC - LUN #0 (Channel #00h)                 
586 	01/19/2011-09:56:57  	Physical Security (Chassis Intrusion	Informational event: Physical Scrty reports LAN Leash has been regained.                                                                                                                                                                                  	BMC - LUN #0 (Channel #00h)                 
587 	01/19/2011-10:34:22  	Physical Security (Chassis Intrusion	Warning event: Physical Scrty reports LAN Leash has been lost.                                                                                                                                                                                            	BMC - LUN #0 (Channel #00h)                 
588 	01/19/2011-10:35:03  	Physical Security (Chassis Intrusion	Informational event: Physical Scrty reports LAN Leash has been regained.                                                                                                                                                                                  	BMC - LUN #0 (Channel #00h)                 
589 	01/19/2011-10:37:02  	Physical Security (Chassis Intrusion	Warning event: Physical Scrty reports LAN Leash has been lost.                                                                                                                                                                                            	BMC - LUN #0 (Channel #00h)                 
590 	01/19/2011-10:37:53  	Physical Security (Chassis Intrusion	Informational event: Physical Scrty reports LAN Leash has been regained.                                                                                                                                                                                  	BMC - LUN #0 (Channel #00h)                 
591 	01/19/2011-10:39:10  	OS Stop / Shutdown #0x00            	Warning event: System Management Software states that OS Stop/Shutdown sensor 0 reports a OS graceful shutdown.                                                                                                                                           	System Management Software (Channel #00h)   
592 	01/19/2011-10:39:10  	OEM Event                           	Operating system shutdown                                                                                                                                                                                                                                 	 OEM Event                                  
593 	01/19/2011-10:39:14  	System Event #0x83                  	Informational event: System Event sensor 131 reports Timestamp Clock Sync. Event is first of two expected events from BIOS on every power on.                                                                                                             	BIOS (Channel #00h)                         
594 	01/19/2011-10:39:16  	System Event #0x83                  	Informational event: System Event sensor 131 reports Timestamp Clock Sync. Event is first of two expected events from BIOS on every power on.                                                                                                             	BIOS (Channel #00h)                         
595 	01/19/2011-10:39:16  	Power Unit /Pwr Unit Redund (#0x02) 	Informational event: Pwr Unit Redund reports full redundancy has been regained .                                                                                                                                                                          	BMC - LUN #0 (Channel #00h)                 
596 	01/19/2011-10:39:22  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is first of two expected events from BIOS on every power on.                                                                                                                     	BIOS (Channel #00h)                         
597 	01/19/2011-10:39:19  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is second of two expected events from BIOS on every power on.                                                                                                                    	BIOS (Channel #00h)                         
598 	01/19/2011-10:42:02  	Power Unit /Pwr Unit Redund (#0x02) 	Informational event: Pwr Unit Redund reports full redundancy has been regained .                                                                                                                                                                          	BMC - LUN #0 (Channel #00h)                 
599 	01/19/2011-10:42:05  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is first of two expected events from BIOS on every power on.                                                                                                                     	BIOS (Channel #00h)                         
600 	01/19/2011-10:42:05  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is second of two expected events from BIOS on every power on.                                                                                                                    	BIOS (Channel #00h)                         
601 	01/19/2011-10:43:13  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports a system boot event has occurred.                                                                                                                                                                            	BIOS (Channel #00h)                         
602 	01/19/2011-10:43:36  	OS Boot #0x00                       	Informational event: System Management Software states that OS Boot sensor 0 reports the boot from drive C has been completed.                                                                                                                            	System Management Software (Channel #00h)   
603 	01/19/2011-10:43:36  	OEM Event                           	Operating system bootup                                                                                                                                                                                                                                   	 OEM Event                                  
604 	01/19/2011-12:48:54  	Physical Security (Chassis Intrusion	Warning event: Physical Scrty reports LAN Leash has been lost.                                                                                                                                                                                            	BMC - LUN #0 (Channel #00h)                 
605 	01/19/2011-12:48:59  	Physical Security (Chassis Intrusion	Informational event: Physical Scrty reports LAN Leash has been regained.                                                                                                                                                                                  	BMC - LUN #0 (Channel #00h)                 
606 	01/19/2011-13:03:50  	OS Stop / Shutdown #0x00            	Warning event: System Management Software states that OS Stop/Shutdown sensor 0 reports a OS graceful shutdown.                                                                                                                                           	System Management Software (Channel #00h)   
607 	01/19/2011-13:03:50  	OEM Event                           	Operating system shutdown                                                                                                                                                                                                                                 	 OEM Event                                  
608 	01/19/2011-13:03:51  	System Event #0x83                  	Informational event: System Event sensor 131 reports Timestamp Clock Sync. Event is first of two expected events from BIOS on every power on.                                                                                                             	BIOS (Channel #00h)                         
609 	01/19/2011-13:03:53  	System Event #0x83                  	Informational event: System Event sensor 131 reports Timestamp Clock Sync. Event is first of two expected events from BIOS on every power on.                                                                                                             	BIOS (Channel #00h)                         
610 	01/19/2011-13:03:54  	Power Unit /Pwr Unit Redund (#0x02) 	Informational event: Pwr Unit Redund reports full redundancy has been regained .                                                                                                                                                                          	BMC - LUN #0 (Channel #00h)                 
611 	01/19/2011-13:03:58  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is first of two expected events from BIOS on every power on.                                                                                                                     	BIOS (Channel #00h)                         
612 	01/19/2011-13:03:58  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is second of two expected events from BIOS on every power on.                                                                                                                    	BIOS (Channel #00h)                         
613 	01/19/2011-13:24:05  	Power Unit /Pwr Unit Redund (#0x02) 	Informational event: Pwr Unit Redund reports full redundancy has been regained .                                                                                                                                                                          	BMC - LUN #0 (Channel #00h)                 
614 	01/19/2011-13:24:09  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is first of two expected events from BIOS on every power on.                                                                                                                     	BIOS (Channel #00h)                         
615 	01/19/2011-13:24:10  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is second of two expected events from BIOS on every power on.                                                                                                                    	BIOS (Channel #00h)                         
616 	01/19/2011-13:25:39  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports a system boot event has occurred.                                                                                                                                                                            	BIOS (Channel #00h)                         
617 	01/19/2011-13:25:57  	OS Boot #0x00                       	Informational event: System Management Software states that OS Boot sensor 0 reports the boot from drive C has been completed.                                                                                                                            	System Management Software (Channel #00h)   
618 	01/19/2011-13:25:57  	OEM Event                           	Operating system bootup                                                                                                                                                                                                                                   	 OEM Event                                  
619 	01/19/2011-14:19:49  	OS Stop / Shutdown #0x00            	Warning event: System Management Software states that OS Stop/Shutdown sensor 0 reports a OS graceful shutdown.                                                                                                                                           	System Management Software (Channel #00h)   
620 	01/19/2011-14:19:49  	OEM Event                           	Operating system shutdown                                                                                                                                                                                                                                 	 OEM Event                                  
621 	01/19/2011-14:19:49  	System Event #0x83                  	Informational event: System Event sensor 131 reports Timestamp Clock Sync. Event is first of two expected events from BIOS on every power on.                                                                                                             	BIOS (Channel #00h)                         
622 	01/19/2011-14:19:51  	System Event #0x83                  	Informational event: System Event sensor 131 reports Timestamp Clock Sync. Event is first of two expected events from BIOS on every power on.                                                                                                             	BIOS (Channel #00h)                         
623 	01/19/2011-14:19:52  	Power Unit /Pwr Unit Redund (#0x02) 	Informational event: Pwr Unit Redund reports full redundancy has been regained .                                                                                                                                                                          	BMC - LUN #0 (Channel #00h)                 
624 	01/19/2011-14:19:57  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is first of two expected events from BIOS on every power on.                                                                                                                     	BIOS (Channel #00h)                         
625 	01/19/2011-14:19:57  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is second of two expected events from BIOS on every power on.                                                                                                                    	BIOS (Channel #00h)                         
626 	01/19/2011-14:27:08  	Processor /P1 Status (#0x60)        	Informational event: P1 Status reports the processor's presence has been detected.                                                                                                                                                                        	BMC - LUN #0 (Channel #00h)                 
627 	01/19/2011-14:27:08  	Processor /P2 Status (#0x61)        	Informational event: P2 Status reports the processor's presence has been detected.                                                                                                                                                                        	BMC - LUN #0 (Channel #00h)                 
628 	01/19/2011-14:27:12  	Power Supply /PS1 Status (#0x50)    	Informational event: PS1 Status reports the power supply's presence has been detected.                                                                                                                                                                    	BMC - LUN #0 (Channel #00h)                 
629 	01/19/2011-14:27:12  	Power Supply /PS2 Status (#0x51)    	Informational event: PS2 Status reports the power supply's presence has been detected.                                                                                                                                                                    	BMC - LUN #0 (Channel #00h)                 
630 	01/19/2011-14:27:13  	Power Unit /Pwr Unit Redund (#0x02) 	Informational event: Pwr Unit Redund reports full redundancy has been regained .                                                                                                                                                                          	BMC - LUN #0 (Channel #00h)                 
631 	01/19/2011-14:45:48  	Processor /P1 Status (#0x60)        	Informational event: P1 Status reports the processor's presence has been detected.                                                                                                                                                                        	BMC - LUN #0 (Channel #00h)                 
632 	01/19/2011-14:45:48  	Processor /P2 Status (#0x61)        	Informational event: P2 Status reports the processor's presence has been detected.                                                                                                                                                                        	BMC - LUN #0 (Channel #00h)                 
633 	01/19/2011-14:45:59  	Power Supply /PS1 Status (#0x50)    	Informational event: PS1 Status reports the power supply's presence has been detected.                                                                                                                                                                    	BMC - LUN #0 (Channel #00h)                 
634 	01/19/2011-14:45:59  	Power Supply /PS2 Status (#0x51)    	Informational event: PS2 Status reports the power supply's presence has been detected.                                                                                                                                                                    	BMC - LUN #0 (Channel #00h)                 
635 	01/19/2011-14:46:00  	Power Unit /Pwr Unit Redund (#0x02) 	Informational event: Pwr Unit Redund reports full redundancy has been regained .                                                                                                                                                                          	BMC - LUN #0 (Channel #00h)                 
636 	01/19/2011-14:46:11  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is first of two expected events from BIOS on every power on.                                                                                                                     	BIOS (Channel #00h)                         
637 	01/19/2011-14:46:12  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is second of two expected events from BIOS on every power on.                                                                                                                    	BIOS (Channel #00h)                         
638 	01/19/2011-14:48:13  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is first of two expected events from BIOS on every power on.                                                                                                                     	BIOS (Channel #00h)                         
639 	01/19/2011-14:48:14  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is second of two expected events from BIOS on every power on.                                                                                                                    	BIOS (Channel #00h)                         
640 	01/19/2011-14:49:52  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports a system boot event has occurred.                                                                                                                                                                            	BIOS (Channel #00h)                         
641 	01/19/2011-14:50:09  	OS Boot #0x00                       	Informational event: System Management Software states that OS Boot sensor 0 reports the boot from drive C has been completed.                                                                                                                            	System Management Software (Channel #00h)   
642 	01/19/2011-14:50:09  	OEM Event                           	Operating system bootup                                                                                                                                                                                                                                   	 OEM Event                                  
643 	01/19/2011-14:56:30  	OS Stop / Shutdown #0x00            	Warning event: System Management Software states that OS Stop/Shutdown sensor 0 reports a OS graceful shutdown.                                                                                                                                           	System Management Software (Channel #00h)   
644 	01/19/2011-14:56:30  	OEM Event                           	Operating system shutdown                                                                                                                                                                                                                                 	 OEM Event                                  
645 	01/19/2011-14:56:30  	System Event #0x83                  	Informational event: System Event sensor 131 reports Timestamp Clock Sync. Event is first of two expected events from BIOS on every power on.                                                                                                             	BIOS (Channel #00h)                         
646 	01/19/2011-14:56:32  	System Event #0x83                  	Informational event: System Event sensor 131 reports Timestamp Clock Sync. Event is first of two expected events from BIOS on every power on.                                                                                                             	BIOS (Channel #00h)                         
647 	01/19/2011-14:56:38  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is first of two expected events from BIOS on every power on.                                                                                                                     	BIOS (Channel #00h)                         
648 	01/19/2011-14:56:39  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is second of two expected events from BIOS on every power on.                                                                                                                    	BIOS (Channel #00h)                         
649 	01/19/2011-15:11:58  	Processor /P1 Status (#0x60)        	Informational event: P1 Status reports the processor's presence has been detected.                                                                                                                                                                        	BMC - LUN #0 (Channel #00h)                 
650 	01/19/2011-15:11:58  	Processor /P2 Status (#0x61)        	Informational event: P2 Status reports the processor's presence has been detected.                                                                                                                                                                        	BMC - LUN #0 (Channel #00h)                 
651 	01/19/2011-15:12:06  	Power Supply /PS1 Status (#0x50)    	Informational event: PS1 Status reports the power supply's presence has been detected.                                                                                                                                                                    	BMC - LUN #0 (Channel #00h)                 
652 	01/19/2011-15:12:06  	Power Supply /PS2 Status (#0x51)    	Informational event: PS2 Status reports the power supply's presence has been detected.                                                                                                                                                                    	BMC - LUN #0 (Channel #00h)                 
653 	01/19/2011-15:12:07  	Power Unit /Pwr Unit Redund (#0x02) 	Informational event: Pwr Unit Redund reports full redundancy has been regained .                                                                                                                                                                          	BMC - LUN #0 (Channel #00h)                 
654 	01/19/2011-15:38:13  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is first of two expected events from BIOS on every power on.                                                                                                                     	BIOS (Channel #00h)                         
655 	01/19/2011-15:38:14  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is second of two expected events from BIOS on every power on.                                                                                                                    	BIOS (Channel #00h)                         
656 	01/19/2011-15:38:20  	Button /Button (#0x09)              	Informational event: Button reports the power button has been pressed.                                                                                                                                                                                    	BMC - LUN #0 (Channel #00h)                 
657 	01/19/2011-15:38:48  	Button /Button (#0x09)              	Informational event: Button reports the power button has been pressed.                                                                                                                                                                                    	BMC - LUN #0 (Channel #00h)                 
658 	01/19/2011-15:38:50  	Power Unit /Pwr Unit Status (#0x01) 	Informational event: Pwr Unit Status reports the power unit is powered off or being powered down.                                                                                                                                                         	BMC - LUN #0 (Channel #00h)                 
659 	01/19/2011-15:39:03  	Power Supply /PS2 Status (#0x51)    	CRITICAL event: PS2 Status reports the power supply has suffered a failure.                                                                                                                                                                               	BMC - LUN #0 (Channel #00h)                 
660 	01/19/2011-15:39:03  	Power Supply /PS2 Status (#0x51)    	Warning event: PS2 Status reports the power supply's input (AC/DC) has been lost.                                                                                                                                                                         	BMC - LUN #0 (Channel #00h)                 
661 	01/19/2011-15:39:04  	Power Unit /Pwr Unit Redund (#0x02) 	Warning event: Pwr Unit Redund reports redundancy has been lost.                                                                                                                                                                                          	BMC - LUN #0 (Channel #00h)                 
662 	01/19/2011-15:39:04  	Power Unit /Pwr Unit Redund (#0x02) 	Warning event: Pwr Unit Redund reports redundancy has been lost .                                                                                                                                                                                         	BMC - LUN #0 (Channel #00h)                 
663 	01/19/2011-15:39:04  	Power Unit /Pwr Unit Redund (#0x02) 	Warning event: Pwr Unit Redund reports redundancy has been lost, but the unit is still functioning with the minimum amount of resources needed for normal operation.                                                                                      	BMC - LUN #0 (Channel #00h)                 
664 	01/19/2011-16:10:47  	Power Unit /Pwr Unit Status (#0x01) 	Informational event: Pwr Unit Status reports the power unit is powered off or being powered down.                                                                                                                                                         	BMC - LUN #0 (Channel #00h)                 
665 	01/19/2011-16:10:49  	Processor /P1 Status (#0x60)        	Informational event: P1 Status reports the processor's presence has been detected.                                                                                                                                                                        	BMC - LUN #0 (Channel #00h)                 
666 	01/19/2011-16:10:49  	Processor /P2 Status (#0x61)        	Informational event: P2 Status reports the processor's presence has been detected.                                                                                                                                                                        	BMC - LUN #0 (Channel #00h)                 
667 	01/19/2011-16:10:58  	Power Supply /PS1 Status (#0x50)    	Informational event: PS1 Status reports the power supply's presence has been detected.                                                                                                                                                                    	BMC - LUN #0 (Channel #00h)                 
668 	01/19/2011-16:10:58  	Power Supply /PS2 Status (#0x51)    	Informational event: PS2 Status reports the power supply's presence has been detected.                                                                                                                                                                    	BMC - LUN #0 (Channel #00h)                 
669 	01/19/2011-16:10:58  	Power Supply /PS2 Status (#0x51)    	CRITICAL event: PS2 Status reports the power supply has suffered a failure.                                                                                                                                                                               	BMC - LUN #0 (Channel #00h)                 
670 	01/19/2011-16:10:58  	Power Supply /PS2 Status (#0x51)    	Warning event: PS2 Status reports the power supply's input (AC/DC) has been lost.                                                                                                                                                                         	BMC - LUN #0 (Channel #00h)                 
671 	01/19/2011-16:11:00  	Power Unit /Pwr Unit Redund (#0x02) 	Warning event: Pwr Unit Redund reports redundancy has been lost .                                                                                                                                                                                         	BMC - LUN #0 (Channel #00h)                 
672 	01/19/2011-16:11:00  	Power Unit /Pwr Unit Redund (#0x02) 	Informational event: Pwr Unit Redund reports the unit has regained the minimum amount of resources needed for normal operation.                                                                                                                           	BMC - LUN #0 (Channel #00h)                 
673 	01/19/2011-16:11:01  	Power Supply /PS2 Status (#0x51)    	Informational event: PS2 Status reports the power supply has recovered from the failure.                                                                                                                                                                  	BMC - LUN #0 (Channel #00h)                 
674 	01/19/2011-16:11:01  	Power Supply /PS2 Status (#0x51)    	Informational event: PS2 Status reports the power supply's input (AC/DC) has been regained.                                                                                                                                                               	BMC - LUN #0 (Channel #00h)                 
675 	01/19/2011-16:11:02  	Power Unit /Pwr Unit Redund (#0x02) 	Informational event: Pwr Unit Redund reports full redundancy has been regained .                                                                                                                                                                          	BMC - LUN #0 (Channel #00h)                 
676 	01/19/2011-16:11:02  	Power Unit /Pwr Unit Redund (#0x02) 	Informational event: Pwr Unit Redund reports full redundancy has been regained.                                                                                                                                                                           	BMC - LUN #0 (Channel #00h)                 
677 	01/19/2011-16:11:02  	Power Unit /Pwr Unit Redund (#0x02) 	Informational event: Pwr Unit Redund reports the unit has regained the minimum amount of resources needed for normal operation.                                                                                                                           	BMC - LUN #0 (Channel #00h)                 
678 	01/19/2011-16:11:04  	Power Unit /Pwr Unit Status (#0x01) 	Informational event: Pwr Unit Status reports the power unit is powered off or being powered down.                                                                                                                                                         	BMC - LUN #0 (Channel #00h)                 
679 	01/19/2011-16:11:04  	Button /Button (#0x09)              	Informational event: Button reports the power button has been pressed.                                                                                                                                                                                    	BMC - LUN #0 (Channel #00h)                 
680 	01/19/2011-16:11:11  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is first of two expected events from BIOS on every power on.                                                                                                                     	BIOS (Channel #00h)                         
681 	01/19/2011-16:11:12  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is second of two expected events from BIOS on every power on.                                                                                                                    	BIOS (Channel #00h)                         
682 	01/19/2011-16:20:33  	Processor /P1 Status (#0x60)        	Informational event: P1 Status reports the processor's presence has been detected.                                                                                                                                                                        	BMC - LUN #0 (Channel #00h)                 
683 	01/19/2011-16:20:33  	Processor /P2 Status (#0x61)        	Informational event: P2 Status reports the processor's presence has been detected.                                                                                                                                                                        	BMC - LUN #0 (Channel #00h)                 
684 	01/19/2011-16:20:41  	Power Supply /PS1 Status (#0x50)    	Informational event: PS1 Status reports the power supply's presence has been detected.                                                                                                                                                                    	BMC - LUN #0 (Channel #00h)                 
685 	01/19/2011-16:20:41  	Power Supply /PS2 Status (#0x51)    	Informational event: PS2 Status reports the power supply's presence has been detected.                                                                                                                                                                    	BMC - LUN #0 (Channel #00h)                 
686 	01/19/2011-16:20:42  	Power Unit /Pwr Unit Redund (#0x02) 	Informational event: Pwr Unit Redund reports full redundancy has been regained .                                                                                                                                                                          	BMC - LUN #0 (Channel #00h)                 
687 	01/19/2011-16:21:12  	Power Supply /PS1 Status (#0x50)    	Informational event: PS1 Status reports the power supply's presence has been lost.                                                                                                                                                                        	BMC - LUN #0 (Channel #00h)                 
688 	01/19/2011-16:21:13  	Power Unit /Pwr Unit Redund (#0x02) 	Warning event: Pwr Unit Redund reports redundancy has been lost.                                                                                                                                                                                          	BMC - LUN #0 (Channel #00h)                 
689 	01/19/2011-16:21:13  	Power Unit /Pwr Unit Redund (#0x02) 	Warning event: Pwr Unit Redund reports redundancy has been lost .                                                                                                                                                                                         	BMC - LUN #0 (Channel #00h)                 
690 	01/19/2011-16:21:13  	Power Unit /Pwr Unit Redund (#0x02) 	Warning event: Pwr Unit Redund reports redundancy has been lost, but the unit is still functioning with the minimum amount of resources needed for normal operation.                                                                                      	BMC - LUN #0 (Channel #00h)                 
691 	01/19/2011-16:21:19  	Power Supply /PS1 Status (#0x50)    	Informational event: PS1 Status reports the power supply's presence has been detected.                                                                                                                                                                    	BMC - LUN #0 (Channel #00h)                 
692 	01/19/2011-16:21:19  	Power Unit /Pwr Unit Redund (#0x02) 	Informational event: Pwr Unit Redund reports full redundancy has been regained .                                                                                                                                                                          	BMC - LUN #0 (Channel #00h)                 
693 	01/19/2011-16:21:19  	Power Unit /Pwr Unit Redund (#0x02) 	Informational event: Pwr Unit Redund reports full redundancy has been regained.                                                                                                                                                                           	BMC - LUN #0 (Channel #00h)                 
694 	01/19/2011-16:21:19  	Power Unit /Pwr Unit Redund (#0x02) 	Informational event: Pwr Unit Redund reports redundancy has been lost, but the unit is still functioning with the minimum amount of resources needed for normal operation.                                                                                	BMC - LUN #0 (Channel #00h)                 
695 	01/19/2011-16:28:07  	Processor /P1 Status (#0x60)        	Informational event: P1 Status reports the processor's presence has been detected.                                                                                                                                                                        	BMC - LUN #0 (Channel #00h)                 
696 	01/19/2011-16:28:07  	Processor /P2 Status (#0x61)        	Informational event: P2 Status reports the processor's presence has been detected.                                                                                                                                                                        	BMC - LUN #0 (Channel #00h)                 
697 	01/19/2011-16:28:20  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is first of two expected events from BIOS on every power on.                                                                                                                     	BIOS (Channel #00h)                         
698 	01/19/2011-16:28:21  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is second of two expected events from BIOS on every power on.                                                                                                                    	BIOS (Channel #00h)                         
699 	01/19/2011-16:28:22  	Button /Button (#0x09)              	Informational event: Button reports the power button has been pressed.                                                                                                                                                                                    	BMC - LUN #0 (Channel #00h)                 
700 	01/19/2011-16:28:25  	Power Unit /Pwr Unit Status (#0x01) 	Informational event: Pwr Unit Status reports the power unit is powered off or being powered down.                                                                                                                                                         	BMC - LUN #0 (Channel #00h)                 
701 	01/20/2011-08:08:15  	Processor /P1 Status (#0x60)        	Informational event: P1 Status reports the processor's presence has been detected.                                                                                                                                                                        	BMC - LUN #0 (Channel #00h)                 
702 	01/20/2011-08:08:15  	Processor /P2 Status (#0x61)        	Informational event: P2 Status reports the processor's presence has been detected.                                                                                                                                                                        	BMC - LUN #0 (Channel #00h)                 
703 	01/20/2011-08:08:17  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is first of two expected events from BIOS on every power on.                                                                                                                     	BIOS (Channel #00h)                         
704 	01/20/2011-08:08:18  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is second of two expected events from BIOS on every power on.                                                                                                                    	BIOS (Channel #00h)                         
705 	01/20/2011-08:15:22  	Processor /P1 Status (#0x60)        	Informational event: P1 Status reports the processor's presence has been detected.                                                                                                                                                                        	BMC - LUN #0 (Channel #00h)                 
706 	01/20/2011-08:15:22  	Processor /P2 Status (#0x61)        	Informational event: P2 Status reports the processor's presence has been detected.                                                                                                                                                                        	BMC - LUN #0 (Channel #00h)                 
707 	01/20/2011-08:15:34  	Power Supply /PS1 Status (#0x50)    	Informational event: PS1 Status reports the power supply's presence has been detected.                                                                                                                                                                    	BMC - LUN #0 (Channel #00h)                 
708 	01/20/2011-08:15:34  	Power Supply /PS2 Status (#0x51)    	Informational event: PS2 Status reports the power supply's presence has been detected.                                                                                                                                                                    	BMC - LUN #0 (Channel #00h)                 
709 	01/20/2011-08:15:34  	Power Supply /PS2 Status (#0x51)    	CRITICAL event: PS2 Status reports the power supply has suffered a failure.                                                                                                                                                                               	BMC - LUN #0 (Channel #00h)                 
710 	01/20/2011-08:15:34  	Power Supply /PS2 Status (#0x51)    	Warning event: PS2 Status reports the power supply's input (AC/DC) has been lost.                                                                                                                                                                         	BMC - LUN #0 (Channel #00h)                 
711 	01/20/2011-08:15:35  	Power Unit /Pwr Unit Redund (#0x02) 	Warning event: Pwr Unit Redund reports redundancy has been lost .                                                                                                                                                                                         	BMC - LUN #0 (Channel #00h)                 
712 	01/20/2011-08:15:35  	Power Unit /Pwr Unit Redund (#0x02) 	Informational event: Pwr Unit Redund reports the unit has regained the minimum amount of resources needed for normal operation.                                                                                                                           	BMC - LUN #0 (Channel #00h)                 
713 	01/20/2011-08:15:36  	Power Supply /PS2 Status (#0x51)    	Informational event: PS2 Status reports the power supply has recovered from the failure.                                                                                                                                                                  	BMC - LUN #0 (Channel #00h)                 
714 	01/20/2011-08:15:36  	Power Supply /PS2 Status (#0x51)    	Informational event: PS2 Status reports the power supply's input (AC/DC) has been regained.                                                                                                                                                               	BMC - LUN #0 (Channel #00h)                 
715 	01/20/2011-08:15:37  	Power Unit /Pwr Unit Redund (#0x02) 	Informational event: Pwr Unit Redund reports full redundancy has been regained .                                                                                                                                                                          	BMC - LUN #0 (Channel #00h)                 
716 	01/20/2011-08:15:37  	Power Unit /Pwr Unit Redund (#0x02) 	Informational event: Pwr Unit Redund reports full redundancy has been regained.                                                                                                                                                                           	BMC - LUN #0 (Channel #00h)                 
717 	01/20/2011-08:15:37  	Power Unit /Pwr Unit Redund (#0x02) 	Informational event: Pwr Unit Redund reports the unit has regained the minimum amount of resources needed for normal operation.                                                                                                                           	BMC - LUN #0 (Channel #00h)                 
718 	01/20/2011-08:15:44  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is first of two expected events from BIOS on every power on.                                                                                                                     	BIOS (Channel #00h)                         
719 	01/20/2011-08:15:45  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is second of two expected events from BIOS on every power on.                                                                                                                    	BIOS (Channel #00h)                         
720 	01/20/2011-08:19:42  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is first of two expected events from BIOS on every power on.                                                                                                                     	BIOS (Channel #00h)                         
721 	01/20/2011-08:19:42  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is second of two expected events from BIOS on every power on.                                                                                                                    	BIOS (Channel #00h)                         
722 	01/20/2011-08:21:42  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is first of two expected events from BIOS on every power on.                                                                                                                     	BIOS (Channel #00h)                         
723 	01/20/2011-08:21:43  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is second of two expected events from BIOS on every power on.                                                                                                                    	BIOS (Channel #00h)                         
724 	01/20/2011-08:22:49  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports a system boot event has occurred.                                                                                                                                                                            	BIOS (Channel #00h)                         
725 	01/20/2011-08:29:45  	Physical Security (Chassis Intrusion	Warning event: Physical Scrty reports LAN Leash has been lost.                                                                                                                                                                                            	BMC - LUN #0 (Channel #00h)                 
726 	01/20/2011-08:40:20  	Physical Security (Chassis Intrusion	Informational event: Physical Scrty reports LAN Leash has been regained.                                                                                                                                                                                  	BMC - LUN #0 (Channel #00h)                 
727 	01/20/2011-08:41:11  	Physical Security (Chassis Intrusion	Warning event: Physical Scrty reports LAN Leash has been lost.                                                                                                                                                                                            	BMC - LUN #0 (Channel #00h)                 
728 	01/20/2011-08:41:19  	Physical Security (Chassis Intrusion	Informational event: Physical Scrty reports LAN Leash has been regained.                                                                                                                                                                                  	BMC - LUN #0 (Channel #00h)                 
729 	01/20/2011-09:08:17  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is first of two expected events from BIOS on every power on.                                                                                                                     	BIOS (Channel #00h)                         
730 	01/20/2011-09:08:18  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is second of two expected events from BIOS on every power on.                                                                                                                    	BIOS (Channel #00h)                         
731 	01/20/2011-09:13:23  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is first of two expected events from BIOS on every power on.                                                                                                                     	BIOS (Channel #00h)                         
732 	01/20/2011-09:13:23  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is second of two expected events from BIOS on every power on.                                                                                                                    	BIOS (Channel #00h)                         
733 	01/20/2011-09:13:39  	Power Unit /Pwr Unit Status (#0x01) 	Informational event: Pwr Unit Status reports the power unit is powered off or being powered down.                                                                                                                                                         	BMC - LUN #0 (Channel #00h)                 
734 	01/20/2011-09:13:39  	Button /Button (#0x09)              	Informational event: Button reports the power button has been pressed.                                                                                                                                                                                    	BMC - LUN #0 (Channel #00h)                 
735 	01/20/2011-09:17:37  	Power Supply /PS1 Status (#0x50)    	Informational event: PS1 Status reports the power supply's presence has been detected.                                                                                                                                                                    	BMC - LUN #0 (Channel #00h)                 
736 	01/20/2011-09:17:37  	Power Supply /PS1 Status (#0x50)    	CRITICAL event: PS1 Status reports the power supply has suffered a failure.                                                                                                                                                                               	BMC - LUN #0 (Channel #00h)                 
737 	01/20/2011-09:17:37  	Power Supply /PS1 Status (#0x50)    	Warning event: PS1 Status reports the power supply's input (AC/DC) has been lost.                                                                                                                                                                         	BMC - LUN #0 (Channel #00h)                 
738 	01/20/2011-09:17:37  	Power Supply /PS2 Status (#0x51)    	Informational event: PS2 Status reports the power supply's presence has been detected.                                                                                                                                                                    	BMC - LUN #0 (Channel #00h)                 
739 	01/20/2011-09:17:38  	Power Unit /Pwr Unit Redund (#0x02) 	Warning event: Pwr Unit Redund reports redundancy has been lost .                                                                                                                                                                                         	BMC - LUN #0 (Channel #00h)                 
740 	01/20/2011-09:17:38  	Power Unit /Pwr Unit Redund (#0x02) 	Informational event: Pwr Unit Redund reports the unit has regained the minimum amount of resources needed for normal operation.                                                                                                                           	BMC - LUN #0 (Channel #00h)                 
741 	01/20/2011-09:17:40  	Power Supply /PS1 Status (#0x50)    	Informational event: PS1 Status reports the power supply has recovered from the failure.                                                                                                                                                                  	BMC - LUN #0 (Channel #00h)                 
742 	01/20/2011-09:17:40  	Power Supply /PS1 Status (#0x50)    	Informational event: PS1 Status reports the power supply's input (AC/DC) has been regained.                                                                                                                                                               	BMC - LUN #0 (Channel #00h)                 
743 	01/20/2011-09:17:41  	Power Unit /Pwr Unit Redund (#0x02) 	Informational event: Pwr Unit Redund reports full redundancy has been regained .                                                                                                                                                                          	BMC - LUN #0 (Channel #00h)                 
744 	01/20/2011-09:17:41  	Power Unit /Pwr Unit Redund (#0x02) 	Informational event: Pwr Unit Redund reports full redundancy has been regained.                                                                                                                                                                           	BMC - LUN #0 (Channel #00h)                 
745 	01/20/2011-09:17:41  	Power Unit /Pwr Unit Redund (#0x02) 	Informational event: Pwr Unit Redund reports the unit has regained the minimum amount of resources needed for normal operation.                                                                                                                           	BMC - LUN #0 (Channel #00h)                 
746 	01/20/2011-09:17:48  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is first of two expected events from BIOS on every power on.                                                                                                                     	BIOS (Channel #00h)                         
747 	01/20/2011-09:17:48  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is second of two expected events from BIOS on every power on.                                                                                                                    	BIOS (Channel #00h)                         
748 	01/20/2011-09:18:52  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports a system boot event has occurred.                                                                                                                                                                            	BIOS (Channel #00h)                         
749 	01/20/2011-09:19:04  	OS Boot #0x00                       	Informational event: System Management Software states that OS Boot sensor 0 reports the boot from drive C has been completed.                                                                                                                            	System Management Software (Channel #00h)   
750 	01/20/2011-09:19:04  	OEM Event                           	Operating system bootup                                                                                                                                                                                                                                   	 OEM Event                                  
751 	01/20/2011-10:17:15  	OS Stop / Shutdown #0x00            	Warning event: System Management Software states that OS Stop/Shutdown sensor 0 reports a OS graceful shutdown.                                                                                                                                           	System Management Software (Channel #00h)   
752 	01/20/2011-10:17:15  	OEM Event                           	Operating system shutdown                                                                                                                                                                                                                                 	 OEM Event                                  
753 	01/20/2011-10:17:16  	System Event #0x83                  	Informational event: System Event sensor 131 reports Timestamp Clock Sync. Event is first of two expected events from BIOS on every power on.                                                                                                             	BIOS (Channel #00h)                         
754 	01/20/2011-10:17:17  	System Event #0x83                  	Informational event: System Event sensor 131 reports Timestamp Clock Sync. Event is first of two expected events from BIOS on every power on.                                                                                                             	BIOS (Channel #00h)                         
755 	01/20/2011-10:17:23  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is first of two expected events from BIOS on every power on.                                                                                                                     	BIOS (Channel #00h)                         
756 	01/20/2011-10:17:24  	System Event /BIOS Evt Sensor (#0x83	Informational event: BIOS Evt Sensor reports Timestamp Clock Sync. Event is second of two expected events from BIOS on every power on.                                                                                                                    	BIOS (Channel #00h)                         